  • Part No.38BOS6-0-R
    ManufacturerMSYSTEM
    Size56 Kbytes
    Pages2 pages
    DescriptionOUTPUT RELAY CARD
    Datasheet Summary with AI

    # 38BOS6 DCS Input/Output Relay Card Series

    ## Model & Ordering Information

    ️· Model Number: 38BOS6
    ️· Suffix Code Selection: 38BOS6–❑–R
    - Test Switch: 0 (Without), 1 (With AUTO position)
    - Power Input: R (24V DC)
    ️· Ordering: Specify code number (e.g., 38BOS6-1-R)
    ️· Related Products: Standard Rack (model: 38B ❑)

    ## General Specifications

    ️· Construction: Rack mounted, with front screw terminals and rear connector access.
    ️· Connections:
    - Input: Connector
    - Output: M3.5 screw terminals (nickel-plated steel, 0.8 N·m torque)
    - Power Input: Supplied from connector
    ️· Isolation: Input or power isolated from output.

    ## Input & Output Characteristics

    ️· Input: Status output from a controller
    - 24V DC @30mA min.
    - ON resistance: ≤200Ω
    - OFF resistance: ≥100kΩ
    ️· Output: Dry contact
    - Rating: 250V AC @3A (cosø=1) or 30V DC @3A (resistive load)
    - Minimum switching load: 5V DC @10mA
    ️· Relay Life:
    - Mechanical: 5 × 10⁷ cycles
    - Electrical: 10⁵ cycles
    ️· Relay Protection: External protection recommended for inductive loads.

    ## Installation & Performance

    ️· Power Input: 24V DC ±10%, approx. 60mA (ripple 10% p-p max.)
    ️· Operating Temperature: -5 to +55°C (23 to 131°F)
    ️· Operating Humidity: 30 to 90% RH (non-condensing)
    ️· Mounting: Standard Rack 38B ❑
    ️· Dimensions: W24×H110×D110 mm (0.94"×4.33"×4.33")
    ️· Weight: 150 g (0.33 lbs)
    ️· Insulation Resistance: ≥100MΩ with 500V DC
    ️· Dielectric Strength: 1500V AC @1 minute (input/power to output to ground)

    ## Front View & Jumpers

    ️· Test Switch (Test SW): 0 (Without), 1 (With AUTO position)
    ️· LED Indicators: Indicate relay status (ON/OFF) for Channels 1 & 2
    ️· Jumpers: Factory set to position A – C. Affects input/output configurations.

    ## Schematic Circuitry & Connection Diagram

    ️· Includes diagrams illustrating jumper positions (JP11, JP12, JP21, JP22) and connector layout (X1, X2).
    ️· Visual representations of input/output relationships.

    # 38BOS6 DCS Input/Output Relay Card Series

    ## Model & Ordering Information

    ️· Model Number: 38BOS6
    ️· Suffix Code Selection: 38BOS6–❑–R
    - Test Switch: 0 (Without), 1 (With AUTO position)
    - Power Input: R (24V DC)
    ️· Ordering: Specify code number (e.g., 38BOS6-1-R)
    ️· Related Products: Standard Rack (model: 38B ❑)

    ## General Specifications

    ️· Construction: Rack mounted, with front screw terminals and rear connector access.
    ️· Connections:
    - Input: Connector
    - Output: M3.5 screw terminals (nickel-plated steel, 0.8 N·m torque)
    - Power Input: Supplied from connector
    ️· Isolation: Input or power isolated from output.

    ## Input & Output Characteristics

    ️· Input: Status output from a controller
    - 24V DC @30mA min.
    - ON resistance: ≤200Ω
    - OFF resistance: ≥100kΩ
    ️· Output: Dry contact
    - Rating: 250V AC @3A (cosø=1) or 30V DC @3A (resistive load)
    - Minimum switching load: 5V DC @10mA
    ️· Relay Life:
    - Mechanical: 5 × 10⁷ cycles
    - Electrical: 10⁵ cycles
    ️· Relay Protection: External protection recommended for inductive loads.

    ## Installation & Performance

    ️· Power Input: 24V DC ±10%, approx. 60mA (ripple 10% p-p max.)
    ️· Operating Temperature: -5 to +55°C (23 to 131°F)
    ️· Operating Humidity: 30 to 90% RH (non-condensing)
    ️· Mounting: Standard Rack 38B ❑
    ️· Dimensions: W24×H110×D110 mm (0.94"×4.33"×4.33")
    ️· Weight: 150 g (0.33 lbs)
    ️· Insulation Resistance: ≥100MΩ with 500V DC
    ️· Dielectric Strength: 1500V AC @1 minute (input/power to output to ground)

    ## Front View & Jumpers

    ️· Test Switch (Test SW): 0 (Without), 1 (With AUTO position)
    ️· LED Indicators: Indicate relay status (ON/OFF) for Channels 1 & 2
    ️· Jumpers: Factory set to position A – C. Affects input/output configurations.

    ## Schematic Circuitry & Connection Diagram

    ️· Includes diagrams illustrating jumper positions (JP11, JP12, JP21, JP22) and connector layout (X1, X2).
    ️· Visual representations of input/output relationships.

    Part No.38BOS6-0-R
    ManufacturerMSYSTEM
    Size56 Kbytes
    Pages2 pages
    DescriptionOUTPUT RELAY CARD
    ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

    Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
    All Rights Reserved©Alldatasheet.com


    Mirror Sites
    English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
    Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
    Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
    Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
    Family Site : ic2ic.com  |   icmetro.com