1. General Information & Purpose
️· Product: FRT Signal Converter
️· Manufacturer: M-System (likely a European manufacturer, known for industrial signal converters)
️· Purpose: This converter takes an input signal (likely from a sensor or transducer) and converts it to a standard output signal (typically 4-20mA or 0-10V). Think of it as a signal conditioning device. It translates raw sensor data into something easily usable by a PLC, data logger, or other control system.
2. Input Signal Options (What it accepts)
️· Variety of Inputs: The FRT is very flexible. It can handle a wide range of input signals:
- Thermocouples: (J, K, T, E, N, R, S, B) – common temperature sensors.
- RTDs (Resistance Temperature Detectors): Pt100, Pt200, Pt1000.
- mV, V, mA - millivolts, volts, and milliamperes (standard electrical signals).
- Voltage: 0-10V, 0-5V, etc.
- Current: 4-20mA
- Frequency
3. Output Signal Options (What it sends)
️· Standard Industrial Outputs:
- 4-20 mA: A very common current loop signal used in industrial automation.
- 0-10 V: A common voltage signal.
️· Programmability: The output scaling (zero and span) is likely adjustable via DIP switches or other on-board configuration options. This lets you adapt the output to match the requirements of your receiving device.
4. Power Supply
️· Typically 24V DC (likely with a wide tolerance, e.g., 18-30V DC)
️· Some models might have other power options.
5. Configuration & Adjustment
️· DIP Switches: The datasheet strongly implies configuration is done via DIP switches. These switches are used to:
- Select the input type (thermocouple type, RTD type, voltage range, current range, etc.)
- Configure the output scaling (zero and span adjustment)
️· User Manual: The datasheet refers to a user manual for detailed instructions on DIP switch settings.
6. Environmental Considerations
️· Operating Temperature: Likely a wide range (-20°C to +60°C or similar), typical of industrial equipment.
️· Enclosure: The datasheet mentions a "DIN Rail" mounting, indicating a compact, industrial-grade enclosure.
7. Mechanical Details
️· DIN Rail Mounting: Designed for easy installation on a standard DIN rail.
️· Compact Size: Generally small, intended for panel mounting.
8. Key Features/Benefits (Inferred)
️· Versatility: Handles a broad range of input signals.
️· Ease of Configuration: DIP switches make it relatively simple to set up.
️· Industrial Robustness: Built to withstand harsh industrial environments.
️· Isolation: Likely provides electrical isolation between the input and output circuits, protecting the connected devices.
9. Important Notes from the Datasheet
️· User Manual is Essential: The datasheet emphasizes the need to consult the user manual for complete setup instructions and DIP switch configurations.
️· Electrical Isolation: The electrical isolation between the input and output helps protect the receiving device.
1. General Information & Purpose
️· Product: FRT Signal Converter
️· Manufacturer: M-System (likely a European manufacturer, known for industrial signal converters)
️· Purpose: This converter takes an input signal (likely from a sensor or transducer) and converts it to a standard output signal (typically 4-20mA or 0-10V). Think of it as a signal conditioning device. It translates raw sensor data into something easily usable by a PLC, data logger, or other control system.
2. Input Signal Options (What it accepts)
️· Variety of Inputs: The FRT is very flexible. It can handle a wide range of input signals:
- Thermocouples: (J, K, T, E, N, R, S, B) – common temperature sensors.
- RTDs (Resistance Temperature Detectors): Pt100, Pt200, Pt1000.
- mV, V, mA - millivolts, volts, and milliamperes (standard electrical signals).
- Voltage: 0-10V, 0-5V, etc.
- Current: 4-20mA
- Frequency
3. Output Signal Options (What it sends)
️· Standard Industrial Outputs:
- 4-20 mA: A very common current loop signal used in industrial automation.
- 0-10 V: A common voltage signal.
️· Programmability: The output scaling (zero and span) is likely adjustable via DIP switches or other on-board configuration options. This lets you adapt the output to match the requirements of your receiving device.
4. Power Supply
️· Typically 24V DC (likely with a wide tolerance, e.g., 18-30V DC)
️· Some models might have other power options.
5. Configuration & Adjustment
️· DIP Switches: The datasheet strongly implies configuration is done via DIP switches. These switches are used to:
- Select the input type (thermocouple type, RTD type, voltage range, current range, etc.)
- Configure the output scaling (zero and span adjustment)
️· User Manual: The datasheet refers to a user manual for detailed instructions on DIP switch settings.
6. Environmental Considerations
️· Operating Temperature: Likely a wide range (-20°C to +60°C or similar), typical of industrial equipment.
️· Enclosure: The datasheet mentions a "DIN Rail" mounting, indicating a compact, industrial-grade enclosure.
7. Mechanical Details
️· DIN Rail Mounting: Designed for easy installation on a standard DIN rail.
️· Compact Size: Generally small, intended for panel mounting.
8. Key Features/Benefits (Inferred)
️· Versatility: Handles a broad range of input signals.
️· Ease of Configuration: DIP switches make it relatively simple to set up.
️· Industrial Robustness: Built to withstand harsh industrial environments.
️· Isolation: Likely provides electrical isolation between the input and output circuits, protecting the connected devices.
9. Important Notes from the Datasheet
️· User Manual is Essential: The datasheet emphasizes the need to consult the user manual for complete setup instructions and DIP switch configurations.
️· Electrical Isolation: The electrical isolation between the input and output helps protect the receiving device.
| Part No. | FRT |
| Manufacturer | MSYSTEM |
| Size | 114 Kbytes |
| Pages | 4 pages |
| Description | Space-saving Plug-in Signal Conditioners F-UNIT |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |