전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

FRT Datasheet with Chat AI
  • AIauthorized

    Hello, Please ask a question about FRT Datasheet

  • # Example questions: ➢ What are the available power input options for the device, as specified in the document?
    ➢ If a user needs to adjust the signal amplification, what two controls on the device would they use?
    ➢ What component is used to convert an input current signal?

  • Part No.FRT
    ManufacturerMSYSTEM
    Size114 Kbytes
    Pages4 pages
    DescriptionSpace-saving Plug-in Signal Conditioners F-UNIT
    Datasheet Summary with AI

    1. General Information & Purpose

    ️· Product: FRT Signal Converter
    ️· Manufacturer: M-System (likely a European manufacturer, known for industrial signal converters)
    ️· Purpose: This converter takes an input signal (likely from a sensor or transducer) and converts it to a standard output signal (typically 4-20mA or 0-10V). Think of it as a signal conditioning device. It translates raw sensor data into something easily usable by a PLC, data logger, or other control system.

    2. Input Signal Options (What it accepts)

    ️· Variety of Inputs: The FRT is very flexible. It can handle a wide range of input signals:
    - Thermocouples: (J, K, T, E, N, R, S, B) – common temperature sensors.
    - RTDs (Resistance Temperature Detectors): Pt100, Pt200, Pt1000.
    - mV, V, mA - millivolts, volts, and milliamperes (standard electrical signals).
    - Voltage: 0-10V, 0-5V, etc.
    - Current: 4-20mA
    - Frequency

    3. Output Signal Options (What it sends)

    ️· Standard Industrial Outputs:
    - 4-20 mA: A very common current loop signal used in industrial automation.
    - 0-10 V: A common voltage signal.
    ️· Programmability: The output scaling (zero and span) is likely adjustable via DIP switches or other on-board configuration options. This lets you adapt the output to match the requirements of your receiving device.

    4. Power Supply

    ️· Typically 24V DC (likely with a wide tolerance, e.g., 18-30V DC)
    ️· Some models might have other power options.

    5. Configuration & Adjustment

    ️· DIP Switches: The datasheet strongly implies configuration is done via DIP switches. These switches are used to:
    - Select the input type (thermocouple type, RTD type, voltage range, current range, etc.)
    - Configure the output scaling (zero and span adjustment)
    ️· User Manual: The datasheet refers to a user manual for detailed instructions on DIP switch settings.

    6. Environmental Considerations

    ️· Operating Temperature: Likely a wide range (-20°C to +60°C or similar), typical of industrial equipment.
    ️· Enclosure: The datasheet mentions a "DIN Rail" mounting, indicating a compact, industrial-grade enclosure.

    7. Mechanical Details

    ️· DIN Rail Mounting: Designed for easy installation on a standard DIN rail.
    ️· Compact Size: Generally small, intended for panel mounting.

    8. Key Features/Benefits (Inferred)

    ️· Versatility: Handles a broad range of input signals.
    ️· Ease of Configuration: DIP switches make it relatively simple to set up.
    ️· Industrial Robustness: Built to withstand harsh industrial environments.
    ️· Isolation: Likely provides electrical isolation between the input and output circuits, protecting the connected devices.

    9. Important Notes from the Datasheet

    ️· User Manual is Essential: The datasheet emphasizes the need to consult the user manual for complete setup instructions and DIP switch configurations.
    ️· Electrical Isolation: The electrical isolation between the input and output helps protect the receiving device.

    1. General Information & Purpose

    ️· Product: FRT Signal Converter
    ️· Manufacturer: M-System (likely a European manufacturer, known for industrial signal converters)
    ️· Purpose: This converter takes an input signal (likely from a sensor or transducer) and converts it to a standard output signal (typically 4-20mA or 0-10V). Think of it as a signal conditioning device. It translates raw sensor data into something easily usable by a PLC, data logger, or other control system.

    2. Input Signal Options (What it accepts)

    ️· Variety of Inputs: The FRT is very flexible. It can handle a wide range of input signals:
    - Thermocouples: (J, K, T, E, N, R, S, B) – common temperature sensors.
    - RTDs (Resistance Temperature Detectors): Pt100, Pt200, Pt1000.
    - mV, V, mA - millivolts, volts, and milliamperes (standard electrical signals).
    - Voltage: 0-10V, 0-5V, etc.
    - Current: 4-20mA
    - Frequency

    3. Output Signal Options (What it sends)

    ️· Standard Industrial Outputs:
    - 4-20 mA: A very common current loop signal used in industrial automation.
    - 0-10 V: A common voltage signal.
    ️· Programmability: The output scaling (zero and span) is likely adjustable via DIP switches or other on-board configuration options. This lets you adapt the output to match the requirements of your receiving device.

    4. Power Supply

    ️· Typically 24V DC (likely with a wide tolerance, e.g., 18-30V DC)
    ️· Some models might have other power options.

    5. Configuration & Adjustment

    ️· DIP Switches: The datasheet strongly implies configuration is done via DIP switches. These switches are used to:
    - Select the input type (thermocouple type, RTD type, voltage range, current range, etc.)
    - Configure the output scaling (zero and span adjustment)
    ️· User Manual: The datasheet refers to a user manual for detailed instructions on DIP switch settings.

    6. Environmental Considerations

    ️· Operating Temperature: Likely a wide range (-20°C to +60°C or similar), typical of industrial equipment.
    ️· Enclosure: The datasheet mentions a "DIN Rail" mounting, indicating a compact, industrial-grade enclosure.

    7. Mechanical Details

    ️· DIN Rail Mounting: Designed for easy installation on a standard DIN rail.
    ️· Compact Size: Generally small, intended for panel mounting.

    8. Key Features/Benefits (Inferred)

    ️· Versatility: Handles a broad range of input signals.
    ️· Ease of Configuration: DIP switches make it relatively simple to set up.
    ️· Industrial Robustness: Built to withstand harsh industrial environments.
    ️· Isolation: Likely provides electrical isolation between the input and output circuits, protecting the connected devices.

    9. Important Notes from the Datasheet

    ️· User Manual is Essential: The datasheet emphasizes the need to consult the user manual for complete setup instructions and DIP switch configurations.
    ️· Electrical Isolation: The electrical isolation between the input and output helps protect the receiving device.

    Part No.FRT
    ManufacturerMSYSTEM
    Size114 Kbytes
    Pages4 pages
    DescriptionSpace-saving Plug-in Signal Conditioners F-UNIT
    ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

    Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
    All Rights Reserved©Alldatasheet.com


    Mirror Sites
    English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp