전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

R-531.2DA Datasheet with Chat AI
  • AIauthorized

    Hello, Please ask a question about R-531.2DA Datasheet

  • # Example questions: ➢ What is the purpose of the resistor network used for adjusting the output voltage?
    ➢ If you need to design a 5v output converter using the r-78 series, what resistor values would you choose for r1 and r2?
    ➢ What are the possible output voltage ranges for the r-78 series dc-dc converters, according to the provided datasheet?

  • Part No.R-531.2DA
    ManufacturerRECOM
    Size202 Kbytes
    Pages6 pages
    Description2, 3, 4, 5 AMP SIP12 Vertical & Horizontal
    Datasheet Summary with AI

    1. Product Overview

    ️· Type: DC-DC Converter Module
    ️· Series: R-3 series
    ️· Manufacturer: RECOM (implied, as this is part of their product line.)
    ️· Output Current Ranges: 2A, 3A, and 5A are all mentioned by the table.
    ️· Package: SIP (Single In-line Package) - This is a standard packaging for components, characterized by its linear arrangement of pins.

    2. Key Features & Specifications (Implied/deduced)

    ️· Input Voltage: The datasheet does not specify. This would be found elsewhere in the full datasheet.
    ️· Output Voltage: Adjustable. The table provides a range of possible output voltages (from 0.8V to 5.5V) and the resistor values needed to achieve them.
    ️· Adjustable Output: The output voltage is set using external resistors. The table shows the required resistor values (R1 and R2) for a wide range of output voltages.
    ️· Isolation: Not explicitly stated, but common for RECOM modules.

    3. Output Voltage Setting (Resistor Values)

    The bulk of the document is a table detailing how to set the output voltage by selecting appropriate values for two external resistors (R1 and R2).

    ️· Voltage Range: 0.8V to 5.5V (adjustable)
    ️· Resistor Network: Uses a voltage divider configuration (the values of R1 and R2 determine the output voltage).
    ️· Table Columns:
    - Output Voltage (V): The desired output voltage.
    - R1 (Ω): The resistance value for resistor 1.
    - R2 (Ω): The resistance value for resistor 2.
    - (Some entries also provide additional resistor combinations for specific output voltages.)

    4. Important Considerations

    ️· Resistor Tolerance: The datasheet likely specifies acceptable tolerance for the resistors to ensure the output voltage is within specification.
    ️· Maximum Input Voltage: The datasheet would specify the maximum input voltage allowed.
    ️· Efficiency: The datasheet would indicate the efficiency of the converter.
    ️· Isolation Voltage: If isolated, the datasheet would specify the isolation voltage.
    ️· Safety Standards: The datasheet would indicate if the module meets any relevant safety standards.

    1. Product Overview

    ️· Type: DC-DC Converter Module
    ️· Series: R-3 series
    ️· Manufacturer: RECOM (implied, as this is part of their product line.)
    ️· Output Current Ranges: 2A, 3A, and 5A are all mentioned by the table.
    ️· Package: SIP (Single In-line Package) - This is a standard packaging for components, characterized by its linear arrangement of pins.

    2. Key Features & Specifications (Implied/deduced)

    ️· Input Voltage: The datasheet does not specify. This would be found elsewhere in the full datasheet.
    ️· Output Voltage: Adjustable. The table provides a range of possible output voltages (from 0.8V to 5.5V) and the resistor values needed to achieve them.
    ️· Adjustable Output: The output voltage is set using external resistors. The table shows the required resistor values (R1 and R2) for a wide range of output voltages.
    ️· Isolation: Not explicitly stated, but common for RECOM modules.

    3. Output Voltage Setting (Resistor Values)

    The bulk of the document is a table detailing how to set the output voltage by selecting appropriate values for two external resistors (R1 and R2).

    ️· Voltage Range: 0.8V to 5.5V (adjustable)
    ️· Resistor Network: Uses a voltage divider configuration (the values of R1 and R2 determine the output voltage).
    ️· Table Columns:
    - Output Voltage (V): The desired output voltage.
    - R1 (Ω): The resistance value for resistor 1.
    - R2 (Ω): The resistance value for resistor 2.
    - (Some entries also provide additional resistor combinations for specific output voltages.)

    4. Important Considerations

    ️· Resistor Tolerance: The datasheet likely specifies acceptable tolerance for the resistors to ensure the output voltage is within specification.
    ️· Maximum Input Voltage: The datasheet would specify the maximum input voltage allowed.
    ️· Efficiency: The datasheet would indicate the efficiency of the converter.
    ️· Isolation Voltage: If isolated, the datasheet would specify the isolation voltage.
    ️· Safety Standards: The datasheet would indicate if the module meets any relevant safety standards.

    Part No.R-531.2DA
    ManufacturerRECOM
    Size202 Kbytes
    Pages6 pages
    Description2, 3, 4, 5 AMP SIP12 Vertical & Horizontal
    ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

    Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
    All Rights Reserved©Alldatasheet.com


    Mirror Sites
    English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
    Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
    Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
    Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
    Family Site : ic2ic.com  |   icmetro.com