| 전자부품 데이터시트 검색엔진 |
|
ATPL230A 데이터시트(PDF) 114 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
ATPL230A 데이터시트(HTML) 114 Page - ATMEL Corporation |
|
114 / 122 page ![]() ATPL230A [DATASHEET] Atmel-43053J-ATPL230A-Datasheet_22-Sep-16 114 10.7 Power On Considerations During power-on, PLL INIT pin should be tied to ground during 4 μs at least, in order to ensure proper system start up. After releasing PLL INIT, the system will start no later than 612 μs. After power-up system can be restarted by means of low active pulse (min 1.65 μs) in ARST or SRST. System full operation starts after 410 μs (ARST pulse) or after 0.9 μs (SRST pulse). In case of simultaneous tie down of more than one initialization pin the longest time for operation must be respected. Figure 10-6. PLL INIT initialization diagram FULL OPERATION PLL INIT ARST SRST > 4us > 612us > 410us > 0.9us > 1.65us* > 1.65us* SYSTEM (*) 1.65us = 33*tclk |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|