| 전자부품 데이터시트 검색엔진 |
|
LTM4686BIVPBF 데이터시트(PDF) 110 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LTM4686BIVPBF 데이터시트(HTML) 110 Page - Analog Devices |
|
110 / 130 page ![]() LTM4686B 110 Rev. 0 For more information www.analog.com APPENDIX C: PMBUS COMMAND DETAILS set and the host notified by asserting the ALERT pin low. CLEAR_FAULTS can take up to 10µs to process. If a fault occurs within that time frame it may be cleared before the status register is set. This write-only command has no data bytes. The CLEAR_FAULTS does not cause a unit that has latched off for a fault condition to restart. Units that have shut down for a fault condition are restarted when: • The output is commanded through the RUN pin, the OPERATION command, or the combined action of the RUN pin and OPERATION command, to turn off and then to turn back on, or • MFR_RESET or RESTORE_USER_ALL command is issued. • Bias power is removed and reapplied to the integrated circuit MFR_CLEAR_PEAKS The MFR_CLEAR_PEAKS command clears the MFR_*_PEAK data values. A MFR_RESET or RESTORE_USER_ALL will initiate this command. This write-only command has no data bytes. SMBALERT_MASK The SMBALERT_MASK command can be used to prevent a particular status bit or bits from asserting ALERT as they are asserted. Figure 58 shows an example of the Write Word format used to set an ALERT mask, in this case without PEC. The bits in the mask byte align with bits in the specified status register. For example, if the STATUS_TEMPERATURE command code is sent in the first data byte, and the mask byte contains 0x40, then a subsequent External Overtemperature Warning would still set bit 6 of STATUS_TEMPERATURE but not assert ALERT. All other supported STATUS_TEMPERATURE bits would continue to assert ALERT if set. Figure 59 shows an example of the Block Write – Block Read Process Call protocol used to read back the present state of any supported status register, again without PEC. SMBALERT_MASK cannot be applied to STATUS_BYTE, STATUS_WORD, MFR_COMMON or MFR_PADS. Factory default masking for applicable status registers is shown below. Providing an unsupported command code to SMBALERT_ MASK will generate a CML for Invalid/Unsupported Data. Figure 58. Example of Setting SMBALERT_MASK Figure 59. Example of Reading SMBALERT_MASK P 1 SLAVE ADDRESS SMBALERT_MASK COMMAND CODE STATUS_x COMMAND CODE W A A S 7 8 8 1 8 1 1 1 1 1 A A MASK BYTE 4686B F58 SLAVE ADDRESS SMBALERT_MASK COMMAND CODE BLOCK COUNT (= 1) W A A S 7 8 8 1 STATUS_x COMMAND CODE 8 1 1 1 1 1 A A … Sr 1 BLOCK COUNT (= 1) A NA P 4686B F59 A 8 8 1 1 1 1 MASK BYTE SLAVE ADDRESS 7 R 1 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |