585 / 1250 page ![]() Section 15 Serial Communication Interface with FIFO (SCIF) Rev. 2.00 Aug. 20, 2008 Page 537 of 1198 REJ09B0403-0200 (5) Data Reception Figure 15.10 shows an example of the data reception flowchart. Read FLSR Receive data ready interrupt Read receive FIFO Read FLSR Error processing (Transmission/reception standby flow) BI = 1, FE = 1, PE = 1, or OE = 1 DR = 0 No Yes [1] [2] [3] [4] [1] When data is received, a receive data ready interrupt occurs. Go to the data reception flow by using this interrupt trigger. [2] Confirm that the BI, FE, PE, and OE flags in FLSR are all cleared. If any one of these flags is set to 1, perform error processing. [3] Read the receive FIFO. [4] Check the DR flag in FLSR. When the DR flag is cleared and all of the data has been read, data reception is complete. Figure 15.10 Example of Data Reception Flowchart |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|