927 / 1250 page ![]() Section 22 USB Function Module (USB) Rev. 2.00 Aug. 20, 2008 Page 879 of 1198 REJ09B0403-0200 22.5.7 EP3 Interrupt-In Transfer USB function Application IN token reception Data transmission to host Set EP3 transmission complete flag (IFR1.EP3 TS = 1) Write data to EP3 data register (EPDR3) Write 1 to EP3 packet enable bit (TRG.EP3 PKTE = 1) Clear EP3 transmission complete flag (IFR1.EP3 TS = 0) Write data to EP3 data register (EPDR3) Write 1 to EP3 packet enable bit (TRG.EP3 PKTE = 1) Valid data in EP3FIFO? Is there data for transmission to host? Is there data for transmission to host? No Yes No Yes No Yes NAK ACK Note: This flowchart shows just one example of interrupt transfer processing. Other possibilities include an operation flow in which, if there is data to be transferred, the EP3 DE bit in the data status register is referenced to confirm that the FIFO is empty, and then data is written to the FIFO. Interrupt request Figure 22.17 Operation of EP3 Interrupt-In Transfer |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|