| 전자부품 데이터시트 검색엔진 |
|
M16C/62M 데이터시트(PDF) 495 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
M16C/62M 데이터시트(HTML) 495 Page - Renesas Technology Corp |
|
495 / 615 page ![]() Power Control Mitsubishi microcomputers M16C / 62A Group SINGLE-CHIP 16-BIT CMOS MICROCOMPUTER 2-178 2.15.2 Stop Mode Set-Up (1) Enables the interrupt used for returning from stop mode. (2) Sets the interrupt enable flag (I flag) to “1”. (3) Clearing the protection and setting all clock stop control bit to “1” stops oscillation and causes the processor to go into stop mode. Operation Settings and operation for entering stop mode are described here. Figure 2.15.5. Example of stop mode set-up All clocks off (stop mode) b7 b0 (3) Canceling protect Protect register [Address 000A16] PRCR 1 Enables writing to system clock control registers 0 and 1 (addresses 000616 and 000716) 1 : Write-enabled (3) All clocks off (stop mode) b7 b0 System clock control register [Address 000716] CM1 0000 Reserved bit Must always be set to “0” All clock stop control bit 1 : All clocks off (stop mode) 1 Interrupt control register TBiIC(i=3 to 5) [Address 004516 to 004716] BCNIC [Address 004A16] KUPIC [Address 004D16] SiTIC(i=0 to 2) [Address 005116, 005316, 004F16] SiRIC(i=0 to 2) [Address 005216, 005416, 005016] TAiIC(i=0 to 4) [Address 005516 to 005916] TBiIC(i=0 to 2) [Address 005A16 to 005C16] (1) Setting interrupt to cancel stop mode Make sure that the interrupt priority level of the interrupt which is used to cancel the wait mode is higher than the processor interrupt priority(IPL) of the routine where the WAIT instruction is executed. Interrupt priority level select bit b7 b0 INTiIC(i=3) [Address 004416] SiIC/INTjIC(i=4, 3) [Address 004816, 004916] (j=3, 4) [Address 004816, 004916] INTiIC(i=0 to 2) [Address 005D16 to 005F16] Make sure that the interrupt priority level of the interrupt which is used to cancel the wait mode is higher than the processor interrupt priority(IPL) of the routine where the WAIT instruction is executed. Interrupt priority level select bit b7 b0 0 Reserved bit Must always be set to “0” System clock control register [Address 000616] CM0 (3) Setting operation clock after returning from stop mode On Main clock (XIN-XOUT) stop bit b7 b0 System clock select bit XIN, XOUT As this register becomes setting mentioned above when operating with XIN (count source of BCLK is XIN), the user does not need to set it again. 00 System clock control register 0 [Address 000616] CM0 XCIN-XCOUT generation Port XC select bit b7 b0 System clock select bit XCIN, XCOUT As this register becomes setting mentioned above when operating with XCIN (count source of BCLK is XCIN), the user does not need to set it again. When operating with XIN, set port Xc select bit to “1” before setting system clock select bit to “1”. The both bits cannot be set at the same time. 1 1 (When operating with XCIN after returning) (When operating with XIN after returning) (2) Interrupt enable flag (I flag) “1” Insert at least four NOPs after the instruction that sets the all clock stop control bit to “1”. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |