Back Button H8/3028F Datasheet HTML 516Page - Renesas Technology Corp H8/3028F Datasheet HTML 517Page - Renesas Technology Corp H8/3028F Datasheet HTML 518Page - Renesas Technology Corp H8/3028F Datasheet HTML 519Page - Renesas Technology Corp H8/3028F Datasheet HTML 520Page - Renesas Technology Corp H8/3028F Datasheet HTML 521Page - Renesas Technology Corp H8/3028F Datasheet HTML 522Page - Renesas Technology Corp H8/3028F Datasheet HTML 523Page - Renesas Technology Corp H8/3028F Datasheet HTML 524Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 520 / 923 page
background image
Rev. 2.00, 09/03, page 490 of 890
In receiving, the SCI operates as follows:
• The SCI monitors the communication line. When it detects a start bit (0 bit), the SCI
synchronizes internally and starts receiving.
• Receive data is stored in RSR in order from LSB to MSB.
• The parity bit and stop bit are received.
After receiving these bits, the SCI carries out the following checks:
 Parity check: The number of 1s in the receive data must match the even or odd parity
setting of in the O/
E bit in SMR.
 Stop bit check: The stop bit value must be 1. If there are two stop bits, only the first is
checked.
 Status check: The RDRF flag must be 0, indicating that the receive data can be transferred
from RSR into RDR.
If these all checks pass, the RDRF flag is set to 1 and the received data is stored in RDR. If
one of the checks fails (receive error*), the SCI operates as shown in table 13.11.
Note: * When a receive error occurs, further receiving is disabled. In receiving, the RDRF flag is
not set to 1. Be sure to clear the error flags to 0.
• When the RDRF flag is set to 1, if the RIE bit is set to 1 in SCR, a receive-data-full interrupt
(RXI) is requested. If the ORER, PER, or FER flag is set to 1 and the RIE bit in SCR is also
set to 1, a receive-error interrupt (ERI) is requested.
Table 13.11 Receive Error Conditions
Receive Error Abbreviation Condition
Data Transfer
Overrun error ORER
Receiving of next data ends while
RDRF flag is still set to 1 in SSR
Receive data is not transferred
from RSR to RDR
Framing error FER
Stop bit is 0
Receive data is transferred from
RSR to RDR
Parity error
PER
Parity of received data differs from
even/odd parity setting in SMR
Receive data is transferred from
RSR to RDR



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com