| 전자부품 데이터시트 검색엔진 |
|
ATtiny167 데이터시트(PDF) 164 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
ATtiny167 데이터시트(HTML) 164 Page - ATMEL Corporation |
|
164 / 282 page ![]() 164 7728D–AVR–07/09 ATtiny87/ATtiny167 15.3.3 Data Transport Two types of data may be transported in a frame; signals or diagnostic messages. • Signals Signals are scalar values or byte arrays that are packed into the data field of a frame. A signal is always present at the same position in the data field for all frames with the same identifier. • Diagnostic messages Diagnostic messages are transported in frames with two reserved identifiers. The interpretation of the data field depends on the data field itself as well as the state of the communicating nodes. 15.3.4 Schedule Table The master task (in the master node) transmits frame headers based on a schedule table. The schedule table specifies the identifiers for each header and the interval between the start of a frame and the start of the following frame. The master application may use different schedule tables and select among them. 15.3.5 Compatibility with LIN 1.3 LIN 2.1 is a super-set of LIN 1.3. A LIN 2.1 master node can handle clusters consisting of both LIN 1.3 slaves and/or LIN 2.1 slaves. The master will then avoid requesting the new LIN 2.1 features from a LIN 1.3 slave: • Enhanced checksum, • Re-configuration and diagnostics, • Automatic baud rate detection, • "Response error" status monitoring. LIN 2.1 slave nodes can not operate with a LIN 1.3 master node (e.g. the LIN1.3 master does not support the enhanced checksum). The LIN 2.1 physical layer is backwards compatible with the LIN1.3 physical layer. But not the other way around. The LIN 2.1 physical layer sets greater requirements, i.e. a master node using the LIN 2.1 physical layer can operate in a LIN 1.3 cluster. 15.4 LIN / UART Controller The LIN/UART controller is divided in three main functions: • Tx LIN Header function, • Rx LIN Header function, • LIN Response function. These functions mainly use two services: •Rx service, •Tx service. Because these two services are basically UART services, the controller is also able to switch into an UART function. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |