전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

  • FRN-R-90

  • AI
    The **FRN-R-90** is a specific model of power fuse commonly used in industrial and commercial electrical systems. It belongs to the **Fusetron™** series manufactured by Eaton’s Bussmann Division. Below is a detailed breakdown of its specifications, components, and electronic characteristics. --- ## 1. Technical Specifications The FRN-R-90 is a **Class RK5** dual-element, time-delay fuse. | Property | Value | | :--- | :--- | | **Current Rating** | 90 Amperes | | **Voltage Rating (AC)** | 250 Volts | | **Voltage Rating (DC)** | 125 Volts | | **Interrupting Rating (AC)** | 200,000 RMS Symmetrical Amps | | **Interrupting Rating (DC)** | 20,000 Amps | | **Fuse Class** | Class RK5 | | **Form Factor** | Cartridge style with blade terminals | --- ## 2. Key Electronic Features ### A. Dual-Element Design Unlike a standard single-element fuse, the FRN-R-90 contains two distinct components working in tandem: 1. **Thermal Element:** Handles low-level overloads. It has a specific time-lag feature that allows temporary surges (like motor startups) to pass without blowing the fuse. 2. **Instantaneous Magnetic/Short-Circuit Element:** Designed to react immediately (in less than 0.01 seconds) if a massive short circuit occurs. ### B. Time-Delay Characteristic This part is engineered to provide a minimum of **10 seconds** of delay at 500% of the rated current. This is critical for inductive loads (motors, transformers) where the "inrush current" is significantly higher than the steady-state operating current. ### C. Current Limitation The "RK5" classification means this fuse is current-limiting. In the event of a major short circuit, it physically interrupts the current before it reaches its full peak, protecting downstream sensitive electronic components from electromagnetic forces and thermal stress. --- ## 3. Physical Construction The fuse is built to withstand harsh environments: * **Tube:** Usually made of high-grade fiberglass or melamine for superior arc-quenching and structural integrity. * **End Caps/Blades:** Conductive copper alloy, often tin-plated to prevent oxidation and maintain low contact resistance. * **Rejection Feature:** The "R" in FRN-R stands for "Rejection." It features a specific physical notch in the blade that prevents it from being replaced by a lower-rated or non-current-limiting fuse (like a Class H fuse) in a Class R fuse block. --- ## 4. Typical Applications * **Motor Branch Circuits:** Its time-delay property prevents "nuisance blowing" during motor startup. * **Control Transformers:** Protects against sustained overloads. * **Main Service Disconnects:** Used in building mains where 250V or less is required. * **General Purpose Circuit Protection:** For lighting and heating loads. ---
    ✨ Follow-up Questions
    • ⤷ What is the difference between an RK1 and an RK5 fuse like the FRN-R-90?
    • ⤷ Can the FRN-R-90 be used in a 480V system?
    • ⤷ How do I test if an FRN-R-90 fuse is blown using a multimeter?