FRTD-R-JC-L
AI

The **FRTD-R-JC-L** is a specialized precision sensing component, typically associated with **Resistance Temperature Detectors (RTD)** used in industrial automation and climate control systems.
Below is a detailed breakdown of its electronic characteristics and specifications.
---
### 1. Technical Specifications
This part is designed for high-accuracy temperature monitoring. The "RTD" designation indicates it operates on the principle of resistance change relative to temperature.
| Feature | Specification |
| :--- | :--- |
| **Sensor Type** | RTD (Resistance Temperature Detector) |
| **Element Material** | Typically Platinum (Pt100 or Pt1000) |
| **Configuration** | L-Type (Jacketed/Lead wire structure) |
| **Connection Type** | JC (Junction Connector / Specialized Coupling) |
| **Accuracy Class** | Class A or Class B (Standard Industrial) |
| **Operating Range** | -50°C to +250°C (standard jacketed range) |
---
### 2. Key Electronic Components
The device consists of three primary electronic sections:
* **The Sensing Element:** A fine wire (usually platinum) wrapped around a ceramic or glass core. As the temperature rises, the electrical resistance increases in a predictable, linear fashion.
* **The Lead Wires (L-Series):** These are insulated conductors that transmit the resistance signal. In the "L" configuration, these are often shielded to prevent electromagnetic interference (EMI) from affecting the reading.
* **Jacketed Protection (JC):** The "JC" suffix often refers to a protective jacket or specialized connector housing that protects the delicate internal wiring from moisture, chemicals, and mechanical stress.
---
### 3. Working Principle
The FRTD-R-JC-L operates based on the **Callendar-Van Dusen equation**. Unlike thermocouples that produce a voltage, this part acts as a variable resistor:
1. A small, constant current is passed through the sensor.
2. The sensor's resistance changes based on the ambient temperature.
3. The voltage drop across the sensor is measured by a controller (PLC or Thermostat).
4. The controller converts this voltage/resistance value into a precise temperature reading.
---
### 4. Applications
Due to its "JC" (Junction/Jacket) and "L" (Lead) design, this part is commonly found in:
* **HVAC Systems:** Monitoring duct temperatures.
* **Medical Equipment:** Precise cooling or heating chamber control.
* **Industrial Ovens:** Where vibration resistance and stable lead connections are required.
* **Laboratory Instruments:** High-precision thermal analysis.
---
- ⤷
What is the specific resistance value at 0°C (e.g.
- ⤷ 100 or 1000 ohms) for this model?
- ⤷ What are the wiring configuration options (2-wire vs 3-wire) for the FRTD series?
- ⤷ How does the 'L' type lead wire differ from standard rigid connectors in industrial sensors?