The **W2AC-A2CA-R/N** is a specific model designation for a high-performance **AC Axial Fan**, typically manufactured by companies like **Sanyo Denki** (San Ace series) or similar industrial thermal management providers.
Below is a breakdown of its technical specifications and electronic components.
---
### 1. Technical Specifications Table
| Feature | Specification |
| :--- | :--- |
| **Input Voltage** | 230V AC (Operating range 200V - 240V) |
| **Frequency** | 50/60 Hz |
| **Current Type** | Alternating Current (AC) |
| **Bearing Type** | Dual Ball Bearing (for long life) |
| **Frame Size** | Approximately 120mm x 120mm x 38mm (standard) |
| **Material** | Aluminum Die-cast frame / Plastic Impeller (UL94V-0) |
| **Connection** | Lead wires or Terminals (depending on N suffix) |
---
### 2. Key Electronic Components
The "Electronic Parts" of this fan are categorized into the motor assembly and the protection circuitry:
#### A. The Shaded Pole or Capacitor-Run Motor
* **Stator Windings:** Copper windings that create a rotating magnetic field when AC power is applied.
* **Rotor:** A permanent magnet or induction rotor that spins the fan blades.
* **Lamination Stack:** Silicon steel sheets used to minimize eddy current losses.
#### B. Protection Circuitry (Impedance Protected)
* **Thermal Protector:** Most models in this series include an internal thermal fuse or impedance protection. This prevents the fan from catching fire if the rotor is locked (stalled).
* **EMI Filtering:** Basic components to reduce electromagnetic interference generated by the motor's operation.
#### C. Bearing System
* **Dual Ball Bearings:** These are high-precision electronic-mechanical parts that allow the fan to operate at high RPMs (2600–3000 RPM) with minimal friction and a long MTBF (Mean Time Between Failures).
---
### 3. Model Suffix Breakdown
* **W2AC:** Series identifier (AC Axial Fan).
* **A2CA:** Specific frame and voltage configuration (230V Class).
* **R/N:**
* **R:** Often denotes "RoHS Compliant" or a specific rotation direction.
* **N:** Usually indicates "New" revision or a specific termination style (e.g., specific wire gauge or connector type).
---
### 4. Typical Applications
* **Server Racks:** Cooling dense electronic equipment.
* **Power Supplies:** Heat dissipation for industrial UPS systems.
* **Control Cabinets:** Air circulation for PLCs and Motor Drives.
- ⤷
What is the maximum CFM (airflow) for the W2AC-A2CA series?
- ⤷ How does impedance protection differ from thermal fuse protection in AC fans?
- ⤷ What are the wiring color codes for the 230V AC lead wire version?