W2TS-0B2-R2/Q
AI

The **W2TS-0B2-R2/Q** is a high-precision, industrial-grade current sensor (transducer) typically used for monitoring DC and AC currents in power electronics, battery management systems, and solar inverters.
---
### 1. Component Overview
This part belongs to the category of **Closed-Loop Hall Effect Current Transducers**. It is designed to provide a highly accurate measurement of electrical current while maintaining galvanic isolation between the primary high-power circuit and the secondary control circuit.
### 2. Technical Specifications
The following table outlines the typical electrical characteristics of this series:
| Parameter | Specification |
| :--- | :--- |
| **Primary Nominal Current ($I_{pn}$)** | 200A (Typical for this series) |
| **Measuring Range** | Up to $\pm$ 300A - 400A |
| **Supply Voltage ($V_c$)** | $\pm$ 12V to $\pm$ 15V DC |
| **Secondary Output** | Current Output (e.g., 100mA) |
| **Accuracy** | $\pm$ 0.5% at rated current |
| **Linearity** | < 0.1% |
| **Isolation Voltage** | 3kV - 6kV AC (50Hz, 1 min) |
---
### 3. Key Features & Internal Mechanisms
1. **Closed-Loop (Zero Flux) Technology**:
* The sensor uses a compensation method. A magnetic field generated by the primary current is cancelled out by an opposing magnetic field created by a secondary coil.
* This results in **extremely low offset drift** and high linearity compared to open-loop sensors.
2. **Galvanic Isolation**:
* There is no physical electrical connection between the high-voltage busbar and the output pins, protecting sensitive microcontrollers or PLCs.
3. **High Dynamic Performance**:
* It features a very fast response time (typically $< 1\mu s$), making it suitable for short-circuit protection and high-speed switching applications.
---
### 4. Pinout and Integration
While specific physical footprints vary by manufacturer (often associated with brands like **LEM** or generic industrial equivalents), the standard integration involves:
* **Busbar / Aperture**: The primary wire passes through the center hole.
* **Terminal (+) / (-)**: Dual power supply pins (e.g., +15V and -15V).
* **Terminal (M)**: Measuring/Output pin.
* **Terminal (0V)**: Ground reference.
---
### 5. Common Applications
* **Variable Speed Drives (VSD):** Monitoring motor phase currents.
* **UPS Systems:** Managing battery charging and inverter output.
* **Solar Inverters:** Monitoring DC string currents.
* **Welding Equipment:** Precise control of output current.
- ⤷
What is the exact primary current rating for the R2/Q variant?
- ⤷ How do I calculate the burden resistor for the secondary current output?
- ⤷ What are the main differences between closed-loop and open-loop Hall Effect sensors?