W2TS-223-R2/CE
AI

## Electronic Specifications: W2TS-223-R2/CE
The **W2TS-223-R2/CE** is a high-precision, two-wire isolated signal transmitter designed by **Watanabe Electric Industry**. It is primarily used to convert DC signals (current or voltage) into a standardized output for industrial control systems.
---
### 1. Key Technical Specifications
Below are the primary electronic characteristics for this specific model:
| Parameter | Specification |
| :--- | :--- |
| **Model Type** | 2-Wire Isolated Transmitter |
| **Input Signal** | DC Current or DC Voltage (Configurable) |
| **Output Signal** | 4 to 20 mA DC |
| **Power Supply** | 12 to 45 V DC (Loop-powered) |
| **Accuracy** | Within ±0.1% of span |
| **Response Time** | Approx. 25ms (0 to 90%) |
| **Isolation Strength** | 2000V AC for 1 minute (Input to Output/Case) |
| **Temperature Drift** | ±0.015% of span / °C |
---
### 2. Detailed Electronic Functions
#### A. Power Supply & Loop Operation
This is a **loop-powered** device. It does not require a separate AC power source; instead, it draws its operating current from the 4-20mA output loop. This simplifies wiring significantly in industrial environments.
#### B. Isolation (Galvanic Isolation)
The "Isolated" designation means there is no direct electrical connection between the input circuit and the output circuit. This protects sensitive PLCs or DCS controllers from:
* **Ground Loops:** Differences in potential between different parts of a factory.
* **Signal Noise:** High-frequency interference from nearby motors or drives.
* **Surges:** Unexpected voltage spikes on the input side.
#### C. Adjustments (R2/CE Designation)
* **Zero/Span Adjustments:** The unit features multi-turn potentiometers on the front panel to fine-tune the 4mA (Zero) and 20mA (Span) points.
* **CE Marking:** The "CE" suffix indicates compliance with European safety and electromagnetic compatibility (EMC) standards, ensuring low electromagnetic emissions and high immunity to interference.
---
### 3. Connection Diagram (General)
```text
[ Input Sensor ] --------> [ W2TS-223-R2/CE ] --------> [ DC Power & PLC ]
(Voltage/Current) (1) (+) (+) (3) (24V DC Loop)
(2) (-) (-) (4)
```
---
### 4. Application Use-Case
Typically, this part is used when a sensor (like a pressure transducer or flow meter) provides a signal that is either too weak or prone to noise. The W2TS converts that signal into a robust 4-20mA signal that can travel long distances without loss of accuracy.
- ⤷
What are the specific input range options for the W2TS-223 model?
- ⤷ How do I wire this transmitter to a 24V DC PLC analog input card?
- ⤷ What is the maximum load resistance supported by the 4-20mA output loop?