| 전자부품 데이터시트 검색엔진 |
|
RBCAND21 데이터시트(PDF) 4 Page - Wall Industries,Inc. |
|
|
|||||||||||||||||||||||||||||
RBCAND21 데이터시트(HTML) 4 Page - Wall Industries,Inc. |
|
4 / 5 page ![]() Rev A RBCAND21 SERIES CAN Isolation Transceiver Module Industrial Bus 12/5/2017 Wall Industries, Inc. • 37 Industrial Drive, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: sales@wallindustries.com Page 4 of 5 Fig. 2 As shown in Figure 2, a single CAN-bus network can connect up to 110 single-channel RBCAN isolated CAN transceiver modules. The universal type module can support a max. communication distance of 10km while the high-speed type module can support a max communication distance of 1km with baud rate beyond 40kbps. If looking to access more nodes or longer communication distance, it can be achieved by using CAN repeaters or other expansion equipment. Notes: The communication distance of the bus is related to the communication speed and field application. It can be designed according to the actual application and reference standard. It is recommended that the communication cable is a twisted pair or shielded twisted pair and should stay away from the interference source. For long-distance communication, the terminal resistance value needs to be selected according to the communication distance and the cable impedance and the number of nodes. Fig. 3 Components Parameter C1 C2 1uF/16V LDM CD43-12uH 2. Recommended Port Protection Circuit Fig. 4 Note: Twisted pair shield grounded reliably. Parameter declaration: Components Recommended Parameters Components Recommended Parameters R3 1MΩ R1, R2 2.7Ω/2W C1 102,2kV D1, D2 1N4007 T1 ACM2520-301-2P D3 SMBJ15CA GDT B3D090L When the module is used in harsh field environment, it is susceptible to the large energy of lightning strike. In this case, it is necessary to add protection circuit to the CAN signal port to protect the module from damage and ensure the reliability of bus communication. Figure 2 provides a recommended protection circuit design for the high-energy lightning surges, with a degree of protection related to the selected protection device. Parameter description lists a set of recommended circuit parameters, which can be adjusted according to the actual application situation. Also, when using the shielded cable, the reliable single-point grounding of the shield must be achieved. Note: This recommended parameter is only the recommended value, which is subject to the actual application. Recommended R1, R2 use PTC, D1, D2 use fast recovery diodes. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |