| 전자부품 데이터시트 검색엔진 |
|
PLC-RSP-24UC/21AU 데이터시트(PDF) 6 Page - PHOENIX CONTACT |
|
|
|||||||||||||||||||||||||||||
PLC-RSP-24UC/21AU 데이터시트(HTML) 6 Page - PHOENIX CONTACT |
|
6 / 14 page ![]() Input Description voltage UN Type Order No. Pcs./ Pkt. PLC interface, consisting of base terminal block PLC-BSP…ACT and pluggable miniature relay 24 V DC2) (see catalog part 6, page 32), for mounting on 3 3 3 3 equipped with power contact relay PLC-RSP- 24DC/ACT 29 67 34 5 10 Technical data Input data Nominal input voltage UN Permissible input voltage range Typ. input current at UN Typ. response time at UN Typ. release time at UN Input circuit 24 V DC 24 V DC see diagram catalog part 6, page 25 9 mA 5 ms 8 ms operation indicator, polarity protection diode, damping diode Output data Contact type Contact material Max. switching voltage Min. switching voltage Limiting continuous current Max. inrush current Min. switching current Max. power rating, ohmic load: 24 V DC 48 V DC 60 V DC 110 V DC 220 V DC 250 V AC Min. switching capacity single contact, 1 N/O contact4) AgSnO 250 V AC/DC 2) 12 V AC/DC 6 A on request 10 mA 140 W 20 W 18 W 23 W 40 W 1500 VA 120 mW General data Test voltage input/output Ambient temperature range Duty type rating Inflammability class Mechanical service life Standards/regulations Installation position/assembly Type of connection 4 kV, 50 Hz, 1 min. – 20 °C to + 60 °C 100 % ED V0 in acc. with UL 94 107 cycles IEC 664/IEC 664 A/DIN VDE 0110, contamination class 3, Surge voltage category III, DIN VDE 0160 (in relev. parts), IEC 255/DIN VDE 0435 (in relev. parts), DIN VDE 0106-101: 1986-11, increased insulation I/O 3) as desired, in rows with zero spacing spring cage connection 1) Further input voltages available on request. 2) For voltages higher than 250 V (e.g. L1, L2, L3) between identical terminal blocks of adjacent modules, the PLC-ATP separating plate (see catalog part 6, page 34) should be installed. 3) For protective isolation between identical terminal blocks of adjacent modules, the PLC-ATP separating plate (see catalog part 6, page 34) should be installed. 4) N/C contact on request. Notes: Type of housing: polyamide PA non-reinforced, Color: green, see catalog part 6, page 149 Marking systems and mounting material, see catalog part 3/4. The rated cross section (see catalog part 6, page 151) refers to untreated conductors without ferrules. For the protection of input and output, inductive loads must be dampened with an effective protection circuit. The PLC-ATP separating plate (see catalog part 6, page 34) must always be installed at the beginning and end of a PLC terminal strip. PLC Actuator Interface with Relay – now also with spring cage connection system! PHOENIX CONTACT page 6 of 14 |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |