11 / 20 page ![]() DS2703 SHA-1 Battery Pack Authentication IC 11 of 20 HARDWARE CONFIGURATION The DS2703 uses an open-drain output driver as part of the bidirectional interface circuitry shown in Figure 5. If a bidirectional pin is not available on the bus master, separate output and input pins can be connected together. For normal communication the 1-Wire bus must have a pullup resistor at the bus-master end of the bus. For short line lengths and/or VPULLUP ≥ 3.0V, a value of approximately 4.7k W is recommended. For long line lengths and/or VPULLUP < 3.0V, a value of approximately 2k W is recommended. The idle state for the 1-Wire bus is high. If, for any reason, a bus transaction must be suspended, the bus must be left in the idle state to properly resume the transaction later. Note that if the bus is left low for more than tLOW0, slave devices on the bus begin to interpret the low period as a reset pulse, effectively terminating the transaction. When performing SHA-1 computations, the DS2703 requires a stronger pullup than 4.7k. A P-FET in parallel with the standard pullup can be switched on during computation and then disabled to read the result. When measuring the thermistor RTHM, both the strong pullup and standard pullup should be disabled to allow a weak pullup to form a voltage divider with the thermistor. A voltage A/D connected directly to the 1-Wire bus can then read the voltage drop of the thermistor. Figure 5. 1-Wire Bus Interface Circuitry TRANSACTION SEQUENCE The protocol for accessing the DS2703 through the 1-Wire port is as follows: § Initialization § Net Address Command § Function Command(s) § Data Transfer (not all commands have data transfer) All transactions of the 1-Wire bus begin with an initialization sequence consisting of a reset pulse transmitted by the bus master, followed by a presence pulse simultaneously transmitted by the DS2703 and any other slaves on the bus. The presence pulse tells the bus master that one or more devices are on the bus and ready to operate. For more details, see the 1-Wire Signaling section below. VPULLUP Bus Master DS2703 Rx Tx 4.7K 50K 150 RTHM ~100Ω MOSFET ~1µA Rx Tx Activate THM PACK- DQ COMP COMM Voltage A/D |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |