| 전자부품 데이터시트 검색엔진 |
|
PLD 데이터시트(PDF) 14 Page - Wavelength Electronics, Inc. |
|
|
|||||||||||||||||||||||||||||
PLD 데이터시트(HTML) 14 Page - Wavelength Electronics, Inc. |
|
14 / 21 page ![]() © 2019 www.teamWavelength.com 14 PLD SERIES LASER DIODE DRIVER REMOTE LIMIT STATUS LED CIRCUIT The LIM I Status feature can be used to drive a remote LED up to 15 mA in your control system. Connect the LED as shown in Figure 13. 4 LIM I Status +5V 10 Figure 13. Remote LIM I Status LED SET THE CURRENT LIMIT MORE ACCURATELY The current limit circuit is designed with a small hysteresis, which causes the limit circuit to trip at a slightly lower current than calculated. To fine-tune the current limit, a small offset voltage must be factored in. Use this equation to calculate the hysteresis offset, where V +5V is the supply voltage: Offset (V) = (V +5V – VI_MON) / 25.9 Then add the Offset to V LIMIT calculated on page 12. CHANGE THE PHOTODIODE RANGE, TYPE A & B LASERS The photodiode current range and transfer function can be adjusted by adding an external resistor. This feature is useful when the photodiode current of your laser falls in a range that does not allow maximum measurement sensitivity on the PLD driver. Figure 14 shows the internal resistor network of the PLD and the equations explain the interaction with the external resistor. 14 6 PD Range Switch 554 5 k PD Range = L µ A µ A / V PD Range = H 2.5 V * 106 R || 500 Ω Range = µ A µ A / V 6 R || 500 Ω 10 Transfer Function = 2.5 V * 106 R || 5 kΩ Range = 6 R || 5 kΩ 10 Transfer Function = R || 5 kΩ R + 5000 R * 5000 = R || 500 Ω R + 500 R * 500 = PD Anode COMMON R Internal Electronics External Electronics Ω Ω Figure 14. Adjusting the PD Range, Type A & B Lasers CHANGE THE PHOTODIODE RANGE, TYPE C LASERS The photodiode range and transfer function can be adjusted when using Type C lasers by connecting a ¼ W resistor between the PD Cathode (pin 15) and AUX V+ (pin 1). The PD current range is calculated (units are amps): Range = 2.5 V / (R || 5 kΩ) The transfer function is calculated (units are A / V): Transfer Function = 1 / (R || 5 kΩ) The value of (R || 5 kΩ) is calculated as follows (units are Ω): (R || 5 kΩ) = (R * 5000) / (R + 5000) ADDITIONAL TECHNICAL INFORMATION This section includes useful technical information on these topics: • Remote Limit Status LED Circuit • Set the Current Limit More Accurately • Change the Photodiode Range, Type A & B Lasers • Change the Photodiode Range, Type C Lasers • Change the Analog Input Modulation Transfer Function • External Setpoint Circuit • • Ground the Fan on the PLD1250, PLD5000, and PLD6500 • Fine Tune Deep Modulation • Cable Lengths and High Current • Add Laser Diode Protection for Long Cables • Additional Noise Filtering • Monitor Calibration Circuit • Revision F Timing Characteristics • Product Variations • Output On/Off and Current Limit Timing • Safe Operating Area Calculation |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |