4 / 8 page ![]() Teach First Limit Output 2 Limits Only Teach Second Limit Teach First Limit Teach First Limits Teach Second Limits Push Button Locked out (or Enabled) Output 1 Limits Only Teach Second Limit Both Outputs Together Push Button Lockout (or Enable) T > 0.8 sec > 0.8 sec T T T T T T T T T T T T T T > 0.8 sec T T T T 0.04 sec < T < 0.8 sec Figure 2. Timing programs for remote TEACH programming General Notes on Configuration • The sensor returns to Run mode if the first TEACH condition is not registered within 120 seconds. • After the first limit is taught, the sensor remains in Program mode until the TEACH sequence is finished. • To exit PROGRAM mode without saving any changes, press and hold the programming push button > 2 seconds or hold the Remote line high > 2 seconds (before teaching the second limit). The sensor reverts to the last saved program. Configuring Limits for Either Analog or Discrete Output Note: To exit PROGRAM mode without saving any changes, press and hold the programming push button > 2 seconds or hold the Remote line high > 2 seconds (before teaching the second limit). The sensor reverts to the last saved program. 1. Choose the output for the first set of window limits (analog or discrete). Method Action Result Push Button Press and hold the corresponding button (analog or discrete) until the green Power LED turns Off and the appropriate amber Output LED turns On. Power LED: Off Output LED: On The sensor is waiting for the first limit. Remote Input2 No action required; sensor is ready for first limit teach. None 2. Configure the first limit. Method Action Result Push Button a. Position the target for the first limit. b. Briefly press the same button. Output LED: On flashing The sensor is waiting for the second limit. The first limit is configured. Remote Input a. Position the target for the first limit. b. Configure the first limit. • To configure the first discrete limit, pulse the remote input one time. • To configure the first analog limit, pulse the remote input two times. c. Wait > 0.8 seconds. The first limit is configured. 3. Teach the second limit. Method Action Result Push Button a. Position the target for the second limit. b. Press the button again. The second limit is configured. Power LED: On Output LED: Off The sensor returns to Run mode. Remote Input a. Position the target for the second limit (no time out). b. Pulse the remote input one time to configure the second limit for either discrete or analog. The second limit is configured. 4. Repeat for the other output (analog or discrete) if a second output is desired. 2 0.04 seconds < T < 0.8 seconds U-GAGE® T30 Series with Analog and Discrete Outputs 4 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 57438 Rev. D |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |