전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

SMB1815SF 데이터시트(PDF) 3 Page - Banner Engineering Corp.

부품명 SMB1815SF
상세설명  T30 Series with Analog and Discrete Outputs
PDF  8 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  BANNER [Banner Engineering Corp.]
홈페이지  https://www.bannerengineering.com/us/en.html
Logo BANNER - Banner Engineering Corp.

SMB1815SF 데이터시트(HTML) 3 Page - Banner Engineering Corp.

  SMB1815SF Datasheet HTML 1Page - Banner Engineering Corp. SMB1815SF Datasheet HTML 2Page - Banner Engineering Corp. SMB1815SF Datasheet HTML 3Page - Banner Engineering Corp. SMB1815SF Datasheet HTML 4Page - Banner Engineering Corp. SMB1815SF Datasheet HTML 5Page - Banner Engineering Corp. SMB1815SF Datasheet HTML 6Page - Banner Engineering Corp. SMB1815SF Datasheet HTML 7Page - Banner Engineering Corp. SMB1815SF Datasheet HTML 8Page - Banner Engineering Corp.  
Zoom Inzoom in Zoom Outzoom out
 3 / 8 page
background image
Wiring
NPN
Shield*
*It is recommended that the shield wire be connected to
either earth ground or DC common.
12-24V dc
4-20 mA
or 0-10V
100 mA
Maximum
–
+
1
3
2
4
5
Remote
Teach
Load
Discrete
PNP
Shield*
*It is recommended that the shield wire be connected to
either earth ground or DC common.
12-24V dc
4-20 mA
or 0-10V
100 mA
Maximum
–
+
1
3
2
4
5
Remote
Teach
Load
Discrete
Cabled wiring diagrams are shown. Quick disconnect wiring diagrams are functionally identical.
Configuring a Sensor
Window Limits
Window limits can be taught to the sensor in several ways, using either the push buttons on the back of the sensor or remote input.
Note: When the sensor changes state between PROGRAM and RUN modes, all of the LED indicators turn OFF momentarily,
before the appropriate LEDs come ON as described below. The sensing window limits expand temporarily to full scale (max
range) during PROGRAM mode.
Remote Input
To program the sensor remotely or to disable the keypad, use the Remote Programming function. In addition to programming the sensor, use the
remote input to disable the buttons for security, preventing unauthorized or accidental programming changes. Connect the gray wire of the sensor to
+12 V dc to 24 V dc, with a remote programming switch connected between them.
Note: The impedance of the remote teach input is 55 kΩ.
Programming is accomplished by following the sequence of input pulses. The duration of each pulse (corresponding to a push button “click”), and
the period between multiple pulses, are defined as: 0.04 seconds < T < 0.8 seconds.
Note: To exit PROGRAM mode without saving any changes, hold the Remote line high > 2 seconds (before teaching the second
limit). The sensor reverts to the last saved program.
U-GAGE® T30 Series with Analog and Discrete Outputs
P/N 57438 Rev. D
www.bannerengineering.com - Tel: + 1 888 373 6767
3



Html Pages

1 2 3 4 5 6 7 8


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com