ATS643LSH 데이터시트(PDF) 12 Page - Allegro MicroSystems

부품명 ATS643LSH
상세설명  Self-Calibrating, Zero-Speed Differential Gear Tooth Sensor with Continuous Update
PDF  16 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  ALLEGRO [Allegro MicroSystems]
홈페이지  http://www.allegromicro.com
Logo ALLEGRO - Allegro MicroSystems

ATS643LSH 데이터시트(HTML) 12 Page - Allegro MicroSystems

Back Button ATS643LSH Datasheet HTML 8Page - Allegro MicroSystems ATS643LSH Datasheet HTML 9Page - Allegro MicroSystems ATS643LSH Datasheet HTML 10Page - Allegro MicroSystems ATS643LSH Datasheet HTML 11Page - Allegro MicroSystems ATS643LSH Datasheet HTML 12Page - Allegro MicroSystems ATS643LSH Datasheet HTML 13Page - Allegro MicroSystems ATS643LSH Datasheet HTML 14Page - Allegro MicroSystems ATS643LSH Datasheet HTML 15Page - Allegro MicroSystems ATS643LSH Datasheet HTML 16Page - Allegro MicroSystems  
Zoom Inzoom in Zoom Outzoom out
 12 / 16 page
background image
12
ATS643-DS, Rev. 1
Worcester, Massachusetts 01615-0036 (508) 853-5000
115 Northeast Cutoff, Box 15036
www.allegromicro.com
Allegro MicroSystems, Inc.
Self-Calibrating, Zero-Speed Differential GTS with Continuous Update
ATS643LSH
Start Mode Hysteresis. This feature helps to ensure optimal
self-calibration by rejecting electrical noise and low-amplitude
target vibration during initialization. This prevents AGC from
calibrating the sensor on such spurious signals. Calibration can
be performed using the actual target features.
A typical scenario is shown in figure 6. The hysteresis, POHYS,
is a minimum level of the peak-to-peak amplitude of the internal
analog electrical signal, VPROC, that must be exceeded before the
ATS643 starts to compute switchpoints.
Figure 6. Operation of Start Mode Hysteresis
Position 1. At power-on, the ATS643 begins sampling VPROC.
Position 2. At the point where the Start Mode Hysteresis is exceeded, the device begins to establish switching thresholds (BOP and BRP) using the Con-
tinuous Update algorithm. After this point, Start Mode Hysteresis is no longer a consideration. Note that a valid VPROC value exceeding the Start Mode
Hysteresis can be generated either by a legitimate target feature or by excessive vibration.
Position 3. In this example, the first switchpoint transition is through BOP. and the output transitions from high to low.
If the first switchpoint transition had been through BRP (such as position 4), no output transition would occur because IOUT already would be in the high
polarity. The first transition would occur at position 5 (BOP).
BRP(#1)
BOP(#1)
BOP(#2)
1
3
4
5
5
2
1
2
Start Mode Hysteresis, POHYS
Output Signal, IOUT
Sensor Position Relative to Target
Target Magnetic Profile
Differential Signal, VPROC
Target, Gear



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com