| 전자부품 데이터시트 검색엔진 |
|
PIT46U 데이터시트(PDF) 4 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
PIT46U 데이터시트(HTML) 4 Page - Banner Engineering Corp. |
|
4 / 16 page ![]() Method Action Result Push Button6 Single-click both buttons simultaneously. Pointer icon: moves to the other channel indicator. Remote Input7 Triple-pulse the remote line. NOTE: Triple-pulse will change the display, but will not save. To save Channel Select, make an adjustment to that channel as a TEACH, SET, or Sensor Setup. T T T T T Two-Point Static TEACH (Threshold) • Establishes a single switching threshold • Threshold position is adjustable using “+” and “-” buttons (see Manual Adjust on page 10) Static TEACH is the traditional setup method, used when two conditions can be presented by the user. The sensor locates a single sensing threshold (the switchpoint) midway between the two taught conditions, with the Output ON condition on one side, and the Output OFF condition on the other. The first condition taught is the ON condition. The Output ON and OFF conditions can be reversed by changing Light/Dark Operate status in Setup mode (see Sensor Setup on page 10 ). Static TEACH and Manual Adjust Using Manual Adjust with Static TEACH moves the switching threshold. Sensor positions threshold midway between taught conditions Darkest (no signal) Most Light (saturated signal) Output OFF Output ON 2nd Taught Condition 1st Taught Condition Position adjusted by Manual Adjust Figure 2. Static TEACH (Light Operate shown) Contrast Values 500+ Excellent: Very stable operation. 100-500 Good: Minor sensing variables will not affect sensing reliability. 32-99 Low: Minor sensing variables may affect sensing reliability. 0-31 Marginal: Consider an alternate sensing scheme. Figure 3. Contrast Values 1. Access the Static TEACH Mode. Method Action Result Push Button8 Press and hold the Static (-) button > 2 seconds. • Display flashes “1St” • Arrow icon turns red Remote Input9 No action is required; the sensor is automatically ready for the 1st TEACH condition. 2. TEACH the Output ON condition. Method Action Result Push Button a. Present the Output ON condition. b. Click the Static button. Display flashes “2nd” Remote Input a. Present the Output ON condition. b. Single-pulse the remote line. T 6 0.04 seconds ≤ "Click" ≤ 0.8 seconds 7 0.04 sec. ≤ T ≤ 0.8 seconds 8 0.04 seconds ≤ "Click" ≤ 0.8 seconds 9 0.04 seconds ≤ T ≤ 0.8 seconds D10 Expert™– Dual Discrete Outputs 4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 64154 Rev. G |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |