| 전자부품 데이터시트 검색엔진 |
|
SMB18A 데이터시트(PDF) 4 Page - Banner Engineering Corp. |
|
|
|||||||||||||||||||||||||||||
SMB18A 데이터시트(HTML) 4 Page - Banner Engineering Corp. |
|
4 / 8 page ![]() Push Button Enable/Disable The push button can be disabled using the remote input wire (gray) to prevent unauthorized adjustment. To disable the push button, connect a normally open switch between the remote input wire and dc common or connect the remote input wire to a digital output on PLC. Perform the procedure below to enable or disable the push button. Method Action Result Remote Input3 Pulse the remote line 4-times. T T T T T T T The push button is enabled or disabled, depending on the previous condition. 2-Point Static TEACH Use 2-Point Static TEACH configuration method for applications where both ON and OFF target conditions can be presented to the sensor statically by the operator. The sensor establishes a single sensing threshold (the switchpoint) midway between the two configured conditions, with the Output ON condition on one side and the Output OFF condition on the other. Note: The sensor returns to RUN mode if the first 2-Point Static TEACH condition is not configured within 60 seconds. Note: After the first condition is configured, the sensor remains in 2-Point Static TEACH configuration until the second condition is configured. Switching Hysteresis OFF Threshold Cold Limit Hot Limit 0° C 300° C 2nd taught (Output OFF) Condition 1st taught (Output ON) Condition ON Threshold (Set at midpoint of taught conditions) When object to be sensed is hotter than ambient Switching Hysteresis OFF Threshold Cold Limit Hot Limit 0° C 300° C 1st Taught (Output ON) Condition 2nd Taught (Output OFF) Condition ON Threshold (Set at midpoint of taught conditions) When object to be sensed is colder than ambient Figure 3. 2-Point Static TEACH 1. Access 2-Point Static TEACH configuration. Method Action Result Push Button Press and hold the button for 2 seconds. • Power LED turns Red • Output LED turns Amber Remote Input2 No action required. 2. Present the output ON condition. Method Action Result Push Button Press the button 1-time. • Output LED turns OFF Remote Input Pulse the remote line 1-time. T 2 0.04 sec < T < 0.8 sec T-GAGE® M18T Series Sensor 4 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 120632 Rev. D |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |