4 / 6 page ![]() TFP412 Page 4 of 6 Max. Coverage Area (a) Width x Length (d) ft x ft (m x m) Max. Spacing ft (m) WET PIPE SYSTEM Minimum Flow and Residual Pressure(b, c) Ordinary Temp. Rating 155°F (68°C) Intermediate Temp. Rating 175°F (79°C) Deflector to Ceiling Installation Type Minimum Spacing ft (m) Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3,7 x 3,7) 12 (3,7) 13 (49,2) 8.7 (0,60) 13 (49,2) 8.7 (0,60) 4 in. to 6 in. Recessed using Style 20 Escutcheon or non-recessed per NFPA 13D, 13R, or 13 8 (2,4) 14 x 14 (4,3 x 4,3) 14 (4,3) 14 (53,0) 10.1 (0,70) 14 (53,0) 10.1 (0,70) 16 x 16 (4,9 x 4,9) 16 (4,9) 16 (60,6) 13.2 (0,91) 16 (60,6) 13.2 (0,91) 16 x 18 (4,9 x 5,5) 16 (4,9) 19 (71,9) 18.6 (1,28) 19 (71,9) 18.6 (1,28) 16 x 20 (4,9 x 6,1) 16 (4,9) 23 (87,1) 27.3 (1,88) 23 (87,1) 27.3 (1,88) 18 x 18 (5,5 x 5,5) 18 (5,5) 23 (87,1) 27.3 (1,88) 23 (87,1) 27.3 (1,88) 18 x 20 (5,5 x 6,1) 18 (5,5) 26 (98,4) 34.9 (2,41) 26 (98,4) 34.9 (2,41) 12 x 12 (3,7 x 3,7) 12 (3,7) 13 (49,2) 8.7 (0,60) 13 (49,2) 8.7 (0,60) 6 in. to 12 in. 14 x 14 (4,3 x 4,3) 14 (4,3) 14 (53,0) 10.1 (0,70) 14 (53,0) 10.1 (0,70) 16 x 16 (4,9 x 4,9) 16 (4,9) 17 (64,3) 14.9 (1,03) 17 (64,3) 14.9 (1,03) 16 x 18 (4,9 x 5,5) 16 (4,9) 20 (75,7) 20.7 (1,43) 20 (75,7) 20.7 (1,43) 16 x 20 (4,9 x 6,1) 16 (4,9) 23 (87,1) 27.3 (1,88) 23 (87,1) 27.3 (1,88) 18 x 18 (5,5 x 5,5) 18 (5,5) 23 (87,1) 27.3 (1,88) 23 (87,1) 27.3 (1,88) 18 x 20 (5,5 x 6,1) 18 (5,5) 26 (98,4) 34.9 (2,41) 26 (98,4) 34.9 (2,41) Notes: a. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. b. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. See Hydraulic Design under the Design Criteria section. c. For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area or the flow in accordance with the criteria in this table must be used. d. The Width x Length dimension refers to the Width (backwall where the sprinkler is located) times the Length (horizontal throw of sprinkler). TABLE A WET PIPE SYSTEMS SERIES LFII (TY2334) RESIDENTIAL HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL SPRINKLERS NFPA 13D, 13R AND 13 WET PIPE HYDRAULIC DESIGN CRITERIA |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |