5 / 8 page ![]() Current - peak inrush accuracy (100 Apeak range) 2% of Range ± 20 mA Effect of common mode (typical) 100 V, 100 kHz, 20 A shunt < 15 mA 100 V, 100 kHz, 1 A shunt < 500 μA 100 V, 100 kHz, external shunt < 40 mV Measurement accuracy - frequency Frequency (10 Hz to 20 kHz) 0.1% of Reading, with the peak of the signal extending 10% above and 10% below the DC level Frequency (20 kHz to 1 MHz) 0.1% of Reading, with the peak of the signal extending 25% above and 25% below the DC level Measurement accuracy - power Watts accuracy ± 0.075% of Reading ± 0.075% of Range (PF=1, 45 - 850 Hz) VA accuracy (Vrmsacc x Arms) + (Armsacc x Vrms) VAR accuracy (typical) VA ± VAerror 2 - W ± Werror 2 - VA 2 - W2 PF Accuracy Cos θ -cos [ θ± ( Vh1 ph.err± Ah1 ph.err)] ± 0.002 Measurement accuracy - harmonic magnitude and phase (typical) Voltage harmonics magnitude (10 Hz to 480 kHz) ± 0.02% of Reading ± 0.1% of Range ± (0.04*F)% of Reading ± 0.05 V Voltage harmonics phase ± 0.04 ± [ 0.01 * (Vrange / Vreading )] ± (0.1 / Vrange) ± (0.005 *F ) Current harmonics magnitude (10 Hz to 480 kHz) ± 0.2% of Reading ± 0.1% of Range ± (0.04*F)% of Reading ± (50 µV / Zext) Current harmonics phase ± 0.04 ± [0.01 * (Arange / Areading)] ± (0.001 / Arange * Zext) ± (0.005 *F) Physical characteristics Dimensions mm in Height 102 4.0 Width 223 8.7 Depth 285 11.2 Weight Kg lb Net (without lead set) 3.2 7.0 Temperature C F Operating 0 °C to +40 °C +32 °F to +102 °F Nonoperating -20 °C to +60 °C -4 °F to +140 °F Notes: All stated accuracies are based upon a minimum of a 30-minute warm-up period. Zext is the external shunt impedance used and must be less than or equal to 10 Ohms. If no frequency is measured, then the signal is considered DC for the purpose of accuracy. F is the frequency measured in kHz. In the case of harmonics, F is the harmonic frequency. Specifications are valid from 1 to 100% of range in low bandwidth and after a manual zero has been performed. Values below 1% are typical. In high bandwidth, specifications are valid when the signal is greater than 10% of the range. Harmonic specifications are always valid when the harmonic is greater than 2% of the range. Measurement conditions during calibration: Instrument default settings unless otherwise stated, sine waves applied to V and I inputs, 30 min warm up, ambient temperature 23 °C ±5 °C. Datasheet www.tek.com 5 |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |