| 전자부품 데이터시트 검색엔진 |
|
XRT79L71IB 데이터시트(PDF) 38 Page - Exar Corporation |
|
|
|||||||||||||||||||||||||||||
XRT79L71IB 데이터시트(HTML) 38 Page - Exar Corporation |
|
38 / 441 page ![]() XRT79L71 PRELIMINARY áç áç áç áç REV. P1.0.3 1 - CHANNEL DS3/E3 ATM UNI/PPP COMBO IC 26 B7 RxOHEnable/ RxHDLCDat_5 O Receive Overhead Data Output Interface - Enable Output/Receive HDLC Controller Data Bus - Bit 5 output: The function of this output pin depends upon whether the XRT79L71 has been configured to operate in the Clear-Channel Framer Mode or in the High-Speed HDLC Controller Mode. Clear-Channel Framer Mode - RxOHEnable: The XRT79L71 will assert this output signal for one RxOHClk period when it is safe for the local terminal equipment to sample the data on the RxOH output pin. High-Speed HDLC Controller Mode - RxHDLCDat_5: This output pin along with RxHDLCDat_[4:0], RxHDLCDat_6 and RxHDLCDat_7 functions as the Receive HDLC Controller byte wide output data bus. The Receive HDLC Controller will output the contents of all HDLC frames via this output data bus, upon the rising edge of the RxHDLCClk output signal. Hence, the user's local terminal equipment should be designed/configured to sample this data upon the falling edge of the RxHDLCClk output clock signal. C7 RxOH/ RxHDLCDat_6 O Receive Overhead Data Output Interface - output/Receive HDLC Controller Data Bus - Bit 6 output: The function of this output pin depends upon whether the XRT79L71 has been configured to operate in the Clear-Channel Framer mode or in the High-Speed HDLC Controller Mode. Clear-Channel Framer Mode - RxOH: All overhead bits, which are received via the Receive Section of the XRT79L71 will be output via this output pin, upon the rising edge of RxOHClk. High-Speed HDLC Controller Mode - RxHDLCDat_6: This output pin along with RxHDLCDat_[5:0] and RxHDLCDat_7 functions as the Receive HDLC Controller byte wide output data bus. The Receive HDLC Controller will output the contents of all HDLC frames via this output data bus, upon the rising edge of the RxHDLCClk output signal. Hence, the user's local terminal equipment should be designed/configured to sample this data upon the falling edge of the RxHDLCClk output clock signal. A7 RxOHClk/ RxHDLCClk O Receive Overhead Data Output Interface - clock/Receive HDLC Controller - Clock output: The function of this output pin depends upon whether the XRT79L71 has been configured to operate in the Clear-Channel Framer mode or in the High-Speed HDLC Controller Mode. Clear-Channel Framer Mode - RxOHClk: The XRT79L71 will output the overhead bits within the incoming DS3 or E3 frames via the RxOH output pin, upon the falling edge of this clock signal. As a consequence, the user's local terminal equipment should use the rising edge of this clock signal to sample the data on both the RxOH and RxOHFrame output pins. NOTE: This clock signal is always active. High-Speed HDLC Controller Mode - RxHDLCClk: This output pin functions as the Receive HDLC Controller Data bus clock out- put. The Receive HDLC Controller block outputs the contents of all received HDLC frames via the Receive HDLC Controller Data bus (RxHDLCDat_[7:0]) upon the rising edge of this clock signal. Hence, the user's local terminal equip- ment should be designed/configured to sample this data upon the falling edge of this clock signal. PIN #NAME TYPE DESCRIPTION |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |