| 전자부품 데이터시트 검색엔진 |
|
LS013B7DH05 데이터시트(PDF) 21 Page - Sharp Corporation |
|
|
|||||||||||||||||||||||||||||
LS013B7DH05 데이터시트(HTML) 21 Page - Sharp Corporation |
|
21 / 29 page ![]() SPEC No. LD-26912A MODEL No. LS013B7DH05 PAGE 19 6-6-5 COM Inversion There are two types of inputs, COM signal serial input (EXTMODE=”L”) and external COM signal input (EXTMODE=”H”). EXTMODE=“L” M1:LC polarity inversion flag: If M1 is "H" then VCOM="H" is output. If M1 is "L" then VCOM="L" is output. ※ 1:LC inversion has been changed by M1 flag statement. ※ 2:The periods of plus polarity and minus polarity should be same length as much as possible. EXTMODE="H" (COM inversion timing has two conditions ) SCS SI COM M0 M1 M2 M0 M2 M1 M2 M0 M1 fCOM ※ 2 ※ 2 ※ 1 ※ 1 ※ 1 SCS EXTCOMIN COM ※ 4:LC inversion polarity has been set by the rising edge of EXTCOMIN. ※ 5:The period of EXTCOMIN should be constant. fCOM ※ 5 ※5 ※ 4 fEXTCOMIN twEXTCOMINH ② ※ 4 : the EXTCOMIN input during low period of the SCS signal . |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |