Back Button ZSC31010CEC Datasheet HTML 9Page - Renesas Technology Corp ZSC31010CEC Datasheet HTML 10Page - Renesas Technology Corp ZSC31010CEC Datasheet HTML 11Page - Renesas Technology Corp ZSC31010CEC Datasheet HTML 12Page - Renesas Technology Corp ZSC31010CEC Datasheet HTML 13Page - Renesas Technology Corp ZSC31010CEC Datasheet HTML 14Page - Renesas Technology Corp ZSC31010CEC Datasheet HTML 15Page - Renesas Technology Corp ZSC31010CEC Datasheet HTML 16Page - Renesas Technology Corp ZSC31010CEC Datasheet HTML 17Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 44 page
background image
ZSC31010 Datasheet
© 2016 Integrated Device Technology, Inc.
13
January 20, 2016
)
Tco
T
B
_
Offset
Raw
_
BR
(
)
Tcg
T
1
(
B
_
Gain
ZB
∗
∆
+
+
∗
∗
∆
+
=
)
ZB
SOT
25
.
1
(
ZB
BR
∗
+
=
2.3.
Digital Signal Processor
A digital signal processor (DSP) is used for processing the converted bridge data as well as for performing
temperature correction and for computing the temperature value for output on the digital channel.
The DSP reads correction coefficients from the EEPROM and can correct for
• Bridge Offset
• Bridge Gain
• Variation of Bridge Offset over Temperature (Tco)
• Variation of Bridge Gain over Temperature (Tcg)
• A Single Second Order Effect (SOT - Second Order Term)
The EEPROM contains a single SOT that can be applied to correct one and only one of the following:
• 2
nd order behavior of bridge measurement
• 2
nd order behavior of Tco
• 2
nd order behavior of Tcg
(For more details, see section 3.6.1.)
If the SOT applies to correcting the bridge reading, then the correction formula for the bridge reading is
represented as a two step process as follows:
(1)
(2)
`
Where:
BR
= Corrected Bridge reading that is fed as digital or analog output on Sig™ pin
ZB
= Intermediate result in the calculations
BR_Raw
= Raw Bridge reading from ADC
T_Raw
= Raw Temperature reading converted from PTAT signal
Gain_B
= Bridge gain term
Offset_B
= Bridge offset term
Tcg
= Temperature coefficient gain
Tco
= Temperature coefficient offset
∆T
= (T_Raw - TSETL)
T_Raw
= Raw Temperature reading converted from PTAT signal
TSETL
= Raw PTAT reference value (See Technical Note—ZSC31010, ZSC31015, and ZSSC3015
Calibration Sequence, DLL, and EXE for details.)
SOT
= Second Order Term
Note:
See section 3.6.2.7 for limitations when SOT applies to the bridge reading.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com