| 전자부품 데이터시트 검색엔진 |
|
TMP139AIYAHT 데이터시트(PDF) 20 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TMP139AIYAHT 데이터시트(HTML) 20 Page - Texas Instruments |
|
20 / 58 page ![]() 7.4.4.4 Host I3C Read Operation with PEC As shown in Figure 7-17 and Figure 7-18, when the PEC is enabled by the host, an additional byte is added by the host after sending the register address. The format for the additional byte is described in Table 7-5. Since only one and two byte reads are permitted by the CMD byte, the device shall terminate the read phase after sending one byte of data and PEC byte or two byte of data and PEC byte, followed by the T-bit as 0. In an unlikely case where the host sets the register address as 255, and attempts a read of two bytes, the device result is not guaranteed. S or Sr 0 SA 1 0 HID2 HID1 HID0 R/W=0 RA = Register Address [7:0] ACK/NACK T Data(RA) ... Data(RA+N) T=1 T=1 T=1 PEC Sr or P T=0 Sr 0 SA 1 0 HID2 HID1 HID0 R/W=1 ACK/NACK CMD T R=1 0 0 0 0 PEC T Figure 7-17. I3C Basic Mode Read with PEC enabled Sr 0 SA 1 0 HID2 HID1 HID0 R/W=0 RA = Register Address [7:0] ACK/NACK T Data(RA) ... Data(RA+N) T=1 T=1 T=1 PEC Sr or P T=0 Sr 0 SA 1 0 HID2 HID1 HID0 R/W=1 ACK/NACK S 1 1 1 1 1 1 0 R/W=0 ACK CMD T R=1 0 0 0 0 PEC T Figure 7-18. I3C Basic Mode Read with PEC enabled and IBI Header If the CMD value sent by the host is not valid for TMP139, the device shall NACK the read phase. The TMP139 shall NACK the read phase of the transaction if there was a parity error in the write phase before the Repeated Start. If the host attempts to start a new transaction with a Repeated Start to the same device, then TMP139 shall NACK the device address to indicate an error condition to the host. The host must first clear the parity error condition before performing any new transfer to the TMP139. If there is a PEC error, then the TMP139 shall NACK the read phase of the transaction. If the host attempts to start a new transaction with a Repeated Start to the same device, then TMP139 shall NACK the device address to indicate an existing error condition to the host. The host must first clear the PEC error condition before performing any new transfer to the TMP139. TMP139 SNIS217 – DECEMBER 2020 www.ti.com 20 Submit Document Feedback Copyright © 2021 Texas Instruments Incorporated Product Folder Links: TMP139 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |