| 전자부품 데이터시트 검색엔진 |
|
W2XR-9Z1Z1-R2/Q 데이터시트(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
W2XR-9Z1Z1-R2/Q 데이터시트(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 4 page ![]() MODEL: W2XR W2XR SPECIFICATIONS ES-5503 Rev.7 Page 1/4 http://www.m-system.co.jp/ Space-saving Dual Output Signal Conditioners Mini-MW Series RTD TRANSMITTER (PC programmable) Functions & Features • Accepts direct input from a RTD • 4-wire connection available • Two independent output ranges • Linearization and burnout • PC programmable • High-density mounting Typical Applications • Long distance transmission between the RTD and the transmitter • Combination with intrinsic safety barriers 88.5 (3.48) 29.5 (1.16) 124 (4.88) mm (inch) MODEL: W2XR–[1][2][3]-[4][5] ORDERING INFORMATION • Code number: W2XR-[1][2][3]-[4][5] Specify a code from below for each [1] through [5]. (e.g. W2XR-4Z1V3-M2/N/Q) • Temperature range (e.g. 0 – 100°C) • Output 1 range (e.g. 4 – 20 mA DC) • Output 2 range (e.g. 1 – 5 V DC) • Specify the specification for option code /Q (e.g. /C01/S01/SET) Note: If one of the outputs should be a current range, specify it for the Output 1 to allow a greater load. [1] INPUT RTD 1: JPt 100 (JIS'89) (Usable range: -200 to +500°C, -328 to +932°F; min.span: 20°C, 36°F) 3: Pt 100 (JIS'89) (Usable range: -200 to +650°C, -328 to +1202°F; min.span: 20°C, 36°F) 4: Pt 100 (JIS'97, IEC) (Usable range: -200 to +850°C, -328 to +1562°F; min.span: 20°C, 36°F) 5: Pt 50 Ω (JIS'81) (Usable range: -200 to +649°C, -328 to +1200°F; min.span: 20°C, 36°F) 7: Pt 1000 (Usable range: -200 to +850°C, -328 to +1562°F; min.span: 20°C, 36°F) 9: Cu 10 @25°C (Usable range: -50 to +250°C, -58 to +482°F; min.span: 20°C, 36°F) 0: Specify (Please provide a resistance table.) (Configurator software is used to change the input type and precise range.) [2] OUTPUT 1 Current Z1: Range 0 – 20 mA DC Voltage V2: Range -10 – +10 V DC V3: Range -5 – +5 V DC (Configurator software is used to change output over the described range of the selected suffix code. For changing between suffix codes, set the Output Range Selector on the side of unit before software adjustment.) [3] OUTPUT 2 Same range availability as Output 1 Y: None (Configurator software is used to change output over the described range of the selected suffix code. For changing between suffix codes, set the Output Range Selector on the side of unit before software adjustment.) [4] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) R2: 11 – 27 V DC (Operational voltage range 11 – 27 V, ripple 10 %p-p max.) P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.) [5] OPTIONS (multiple selections) Standards & Approvals (must be specified) /N: Without CE Other Options blank: none /Q: Option other than the above (specify the specification) |
유사한 부품 번호 - W2XR-9Z1Z1-R2/Q |
|
유사한 설명 - W2XR-9Z1Z1-R2/Q |
|
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |