| 전자부품 데이터시트 검색엔진 |
|
XB5AP21 데이터시트(PDF) 2 Page - Schneider Electric |
|
|
|||||||||||||||||||||||||||||
XB5AP21 데이터시트(HTML) 2 Page - Schneider Electric |
|
2 / 5 page ![]() Positive opening Without Operating travel 2.6 mm (NO changing electrical state) 4.3 mm (total travel) Operating force 3.8 N NO changing electrical state Mechanical durability 10000000 cycles Tightening torque 0.8…1.2 N.m conforming to EN 60947-1 Shape of screw head Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver Contacts material Silver alloy (Ag/Ni) Short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 [Ith] conventional free air thermal current 10 A conforming to EN/IEC 60947-5-1 [Ui] rated insulation voltage 600 V (pollution degree 3) conforming to EN/IEC 60947-1 [Uimp] rated impulse withstand voltage 6 kV EN/IEC 60947-1 [Ie] rated operational current 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 Electrical durability 1000000 cycles AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1: appendix C 1000000 cycles AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1: appendix C 1000000 cycles AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1: appendix C 1000000 cycles DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C 1000000 cycles DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1: appendix C Electrical reliability Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 Device presentation Complete product Customizable Yes GCR BRIDGE XB5APCUST01 Compatibility code XB5 Environment Protective treatment TH Ambient air temperature for storage -40…70 °C Ambient air temperature for operation -40…70 °C Overvoltage category Class II conforming to IEC 60536 IP degree of protection IP66 conforming to IEC 60529 IP67 NEMA degree of protection NEMA 13 NEMA 4X IK degree of protection IK03 conforming to IEC 50102 Standards UL 508 EN/IEC 60947-1 JIS C8201-5-1 EN/IEC 60947-5-4 CSA C22.2 No 14 EN/IEC 60947-5-1 JIS C8201-1 Product certifications BV CSA LROS (Lloyds register of shipping) DNV RINA GL UL listed 2 |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |