  48DV-4YVE-R Datasheet HTML 1Page - M-System Co.,Ltd. 48DV-4YVE-R Datasheet HTML 2Page - M-System Co.,Ltd. 48DV-4YVE-R Datasheet HTML 3Page - M-System Co.,Ltd. 48DV-4YVE-R Datasheet HTML 4Page - M-System Co.,Ltd. 48DV-4YVE-R Datasheet HTML 5Page - M-System Co.,Ltd. 48DV-4YVE-R Datasheet HTML 6Page - M-System Co.,Ltd.  
Zoom Inzoom in Zoom Outzoom out
 5 / 6 page
background image
ES-9313 Rev.13
ADJUSTMENT PROCEDURE
P. 5 / 6
L
SET
L
M
SETPOINT CHANGE
L SETPOINT
COMPLETED
LL
SET
LL
M
SETPOINT CHANGE
LL SETPOINT
COMPLETED
2
SET
2
M
SETPOINT CHANGE
SETPOINT 2
COMPLETED
1
SET
1
M
SETPOINT CHANGE
SETPOINT 1
COMPLETED
Z
M
PRESS AT A TIME
ANALOG / DIGITAL
ZERO ADJUSTMENT
Z
SET
Z
M
SETPOINT CHANGE
DIGITAL ZERO
ADJUSTMENT
COMPLETED
Z
LED ON
P
M
PRESS AT A TIME
MOVING AVERAGE
SAMPLE NUMBER
SETPOINT CHANGE
COMPLETED
DIGITAL METER
S
M
PRESS AT A TIME
ANALOG / DIGITAL
SPAN ADJUSTMENT
S
SET
S
M
SETPOINT CHANGE
DIGITAL SPAN
ADJUSTMENT
COMPLETED
S
LED ON
P
SET
M
SETPOINT CHANGE
DECIMAL POINT
POSITION
ADJUSTMENT
COMPLETED
HH
SET
HH
M
SETPOINT CHANGE
LED
BLINKING
HH SETPOINT
COMPLETED
H
SET
H
M
SETPOINT CHANGE
H SETPOINT
COMPLETED
LED OFF
MODE
SELECTOR
ENTER BUTTON
UP-DOWN
OPERATION
BUTTON
P
Remark 1: HH, H, L and LL setpoints are stored in the memory even the power is lost during operation.
If you need to adjust zero and span or digital meter, proceed before alarm setpoint adjustments.
Apply 0% and 100% input and adjust respective analog zero and span.
Remark 2: HH, H, L and LL Setpoint Adj. are deleted with model 48DV-0.
HH and LL Setpoint Adj. are deleted with model 48DV-2.
SET
P
LL
M
PRESS AT A TIME
LL SETPOINT
ON DELAY TIME
COMPLETED
DIGITAL METER
SET
LL
L
M
PRESS AT A TIME
L SETPOINT
ON DELAY TIME
COMPLETED
DIGITAL METER
SET
L
H
M
PRESS AT A TIME
H SETPOINT
ON DELAY TIME
COMPLETED
DIGITAL METER
SET
H
HH
M
PRESS AT A TIME
HH SETPOINT
ON DELAY TIME
COMPLETED
DIGITAL METER
SET
HH



Html Pages

1 2 3 4 5 6


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com