| 전자부품 데이터시트 검색엔진 |
|
MRP4 데이터시트(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
MRP4 데이터시트(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 6 page ![]() MODEL: MRP4 MRP4 SPECIFICATIONS ES-4824 Rev.13 Page 1/6 http://www.m-system.co.jp/ Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features • Small-size control valve actuator • 1/1000 high resolution • Easy adjustment: electronic limiter at the valve open & closed positions • Overload protection • Various power inputs Typical Applications • Actuator for automatic control valve in pilotplants • Air-conditioning in buildings or plants • Micro-flow control for pharmaceutical injection • For small-size control valves MODEL: MRP4–[1][2][3][4]–[5][6][7] ORDERING INFORMATION • Code number: MRP4-[1][2][3][4]-[5][6][7] Specify a code from below for each of [1] through [7]. (e.g. MRP4-14LT-A0R) • Special input range (for codes Z and 0) [1] SPAN 1: 45 to 90 degrees 2: 90 to 180 degrees [2] OPERATION TIME, TORQUE 4: 7 seconds / 90°, 5 N·m 5: 13 seconds / 90°, 5 N·m [3] SEQUENTIAL CONTROL SIGNALS L: Full-open/-closed signal F: Forced open/close signal B: Full-open/-closed and forced open/close signals (Select 'With Terminal Box.') E: Full-closed/overload signal (Not selectable for CE) 0: Without [4] TERMINAL BOX T: With 0: Without [5] INPUT Current A: 4 – 20 mA DC (Input resistance 250 Ω) Z: Specify current (See INPUT SPECIFICATIONS) Voltage 6: 1 – 5 V DC (Input resistance approx. 1 MΩ) 0: Specify voltage (See INPUT SPECIFICATIONS) [6] CE MARKING C: With 0: Without [7] POWER INPUT AC Power K3: 100 – 120 V AC (Operational voltage range 90 – 132 V, 47 – 66 Hz) (Not selectable for CE) L3: 200 – 240 V AC (Operational voltage range 180 – 264 V, 47 – 66 Hz) (Not selectable for CE) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) GENERAL SPECIFICATIONS Degree of protection: IP66 Action: Direct or reverse; field selectable with DIP switches (factory set to “reverse”) (In “reverse” action, the output stem seen from the cover turns counterclockwise with an input signal increase.) Operation at abnormally low input: Counterclockwise turn, clockwise turn or stop; field selectable with DIP switches (factory set to“clockwise”) Note: Counterclockwise or clockwise if seen from the cover. Detectable input drop level: -16 ±2.5 % Electrical connection •Without terminal box Wiring conduit: G 1/2 female; cable connector with 1 meter wire (0.5 mm2) provided •Terminal box Wiring conduit: G 1/2 female (two) Terminal screws: M3 pillar terminal (Sequential control signal suffix code B) M3 chromated steel |
유사한 부품 번호 - MRP4 |
|
유사한 설명 - MRP4 |
|
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |