| 전자부품 데이터시트 검색엔진 |
|
MCP33131 데이터시트(PDF) 39 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
MCP33131 데이터시트(HTML) 39 Page - Microchip Technology |
|
39 / 54 page ![]() 2018 Microchip Technology Inc. DS20006122A-page 39 MCP33131/MCP33121/MCP33111-XX 7.1 Recalibrate Command The user may use the recalibrate command in the following cases: • When the reference voltage was not fully settled during the first-power sequence. • During operation, to ensure optimum performance across varying environment conditions, such as reference voltage and temperature. A self-calibration is initiated by sending the recalibrate command. The host device sends a recalibrate command by transmitting 1024 SCLK pulses (including the clocks for data bits) while the device is in the acquisition phase (Standby). The device drives SDO low during the recalibration procedure, and returns to high-Z once completed. The status of the recalibration procedure can be monitored by placing a pull-up on SDO, so that SDO goes high when the recalibration is complete. Figure 7-3 shows the recalibrate command timing diagram. The calibration takes approximately 500 ms (tCAL). FIGURE 7-3: Recalibrate Command Timing Diagram. Note: When the device performs a self-calibration, it is important to note that both AVDD and the reference voltage (VREF) must be stabilized for a correct calibration. This is also true when the device is first powered-up, the reference voltage (VREF) must be stabilized before self-calibration begins. This means the VREF must be provided prior to supplying AVDD or within about 64 ms after supplying AVDD. 1024 clocks Start recalibration tCAL 16 1 (SPITM Recalibrate command) Hi-Z Hi-Z Note “Low” 1024 “High” with Pull-up Hi-Z ADC Output Data Stream “High” with Pull-up 2: The 1024 clocks include the clocks for data bits. tCNV Complete data reading Finish recalibration Device Recalibration (Note 3) (Note 2) 1: SDI must remain “High” during the entire recalibration cycle. (Note 4) 3: SDO outputs “Low” during calibration, and Hi-Z when exiting the calibration. SDI = DVIO 4: After finishing the recalibration procedure, the device is ready for a new input sampling immediately. (Note 1) CNVST SDO SCLK ADC State 23 15 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |