2 / 4 page ![]() MODEL: R3-AS4 R3-AS4 SPECIFICATIONS ES-8439 Rev.7 Page 2/4 https://www.m-system.co.jp/ PERFORMANCE Conversion accuracy: Refer to the table at the end of this section. Conversion rate: 80 / 40 / 20 / 10 msec. selectable Data allocation: 1 Current consumption: 60 mA Temp. coefficient: ±0.03 %/°C (±0.02 %/°F) Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (input 1 to input 2 to input 3 to input 4 to internal bus or internal power) 2000 V AC @ 1 minute (power input to FG; isolated on the power supply module) 0 – 20 mA -20 – +20 mA RANGE RATE 80 msec. 40 msec. 20 msec. 10 msec. ±0.05% ±0.1% ±0.2% ±0.4% ±0.1% ±0.2% ±0.4% ±0.8% 4 – 20 mA ±0.1% ±0.2% ±0.4% ±0.8% STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 RoHS Directive ALARM SETTING The following parameters are programmable using the PC Configurator Software (model: R3CON). ■ALARM TRIP POINT (-15.00 to +115.00 %; factory set to A1: 80.00, A2: 60.00, A3: 40.00, A4: 20.00) Four alarm setpoints are selectable per each input. ■ALARM TYPE (High or Low; factory set to A1: High, A2: High, A3: Low, A4: Low) High or Low alarm is selectable for each alarm trip point. High alarm: An alarm is set when the input signal goes above the setpoint. Low alarm: An alarm is set when the input signal goes below the setpoint. ■DEADBAND (HYSTERESIS) (0.00 to 100.00 %; factory set to 5.00) Deadband (deviation between the points where the alarm is set and reset) is selectable for each alarm trip point. ■ALARM ON DELAY TIME (0.0 to 99.0 seconds; factory set to 1.0) The alarm output is set when the preset time elapses after the input has entered in the alarm range. This setting is common to all four points. ■POWER ON DELAY TIME (0.0 to 99.0 sec.; factory set to 5.0) The alarm output start functioning in the preset time after the power has been turned on. This setting is common to all four points. ■ALARM HOLD TIME (0.0 to 99.0 seconds; factory set to 1.0) The alarm output is held for the preset time even if it is reset in shorter time. This setting is common to all four points. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |