| 전자부품 데이터시트 검색엔진 |
|
R3-MEX2W/CE 데이터시트(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R3-MEX2W/CE 데이터시트(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 4 page ![]() MODEL: R3-MEX2 R3-MEX2 SPECIFICATIONS ES-8279 Rev.2 Page 2/4 https://www.m-system.co.jp/ OUTPUT SPECIFICATIONS ■ Control Output: SSR (zero-crossing); 20 - 240 V AC 0.1 - 1 A Leakage current at OFF: Approx. 10 mA @ 240 V AC Output operation at loss of communication: When a communication error occurs in the middle of an output operation, the operation continues toward until reaching target position most recently set by Host device. Deviation + – 0 Deadband ▼ Output Operation: (terminal No. in parentheses) (2 – 11) ON to min. (1 – 11) ON to max. Deviation + – 0 Deadband ▼ (7 – 16) ON to min. (6 – 16) ON to max. INSTALLATION Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Installation Base (model: R3-BSx) Weight: 190 g (0.42 lb) PERFORMANCE ■ POSITION FEEDBACK INPUT Conversion accuracy: ±0.4 % The conversion accuracy is defined against the potentiometer's full span. Conversion rate: 10 msec. Data range: 0 – 1000 Data allocation: 4 Current consumption: Approx. 50 mA Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Temperature coefficient is defined against the potentiometer's full span. Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @1 minute (control output 1 to control output 2 to position feedback 1 or position feedback 2 or internal bus or internal power) 2000 V AC @1 minute (power input to FG; isolated on the power supply module) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1, EN 61010-2-201 Measurement Category II (control output) Pollution degree 2 Position feedback 1 or position feedback 2 to control output 1 to control output 2: Reinforced insulation (300 V) RoHS Directive FUNCTIONS • SSR (Solid State Relay) SSR consists only of semiconductor elements, and thus SSR is free from arc discharge and chattering which are typical with electromagnetic relays. SSR has excellent durability against vibration, physical impact, and environmental influences. • Zero-Cross Function SSR with zero-cross function turns on when AC power voltage is near zero. When input is provided in the middle of a wave cycle, SSR delays switching until the next time the voltage becomes near zero, thus limiting transient switching noise voltage and rush current. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |