6 / 39 page ![]() MODEL: R7M R7M SPECIFICATIONS ES-7803 Rev.26 Page 6/39 http://www.m-system.co.jp/ MODBUS FUNCTION CODES & SUPPORTED CODES ■ Data and Control Functions CODE NAME 01 Read Coil Status Digital output from the slave (read/write) 02 Read Input Status Status of digital inputs to the slave (read only) 03 Read Holding Registers General purpose register within the slave (read/write) 04 Read Input Registers Collected data from the eld by the slave (read only) 05 Force Single Coil Digital output from the slave (read/write) 06 Preset Single Register General purpose register within the slave (read/write) 08 Diagnostics 11 Fetch Comm. Event Counter Fetch a status word and an event counter 12 Fetch Comm. Event Log A status word, an event counter, a message count and a eld of event bytes 15 Force Multiple Coils Digital output from the slave (read/write) 16 Preset Multiple Registers General purpose register within the slave (read/write) 17 Report Slave ID Slave type / ‘RUN’status ■ Exception Codes CODE NAME 01 Illegal Function Function code is not allowable for the slave 02 Illegal Data Address Address is not available within the slave 03 Illegal Data Value Data is not valid for the function ■ Diagnostic Subfunctions CODE NAME 00 Return Query Data Loop back test MODBUS I/O ASSIGNMENT ADDRESS DATA TYPE DATA Coil (0X) 1 – 16 Digital Output (discrete output of the basic module) 17 – 32 Digital Output (discrete output of the extension module) Inputs (1X) 1 – 16 Digital Input (discrete input of the basic module) 17 – 32 Digital Input (discrete input of the extension module) 33 – 48 Reserved (unused) 49 – 64 Module Status 65 – 80 Reserved (unused) Input Registers (3X) 1 – 4 I Analog Input 5 – 16 ---- Reserved (unused) 17 – 24 F Analog Input 25 – 48 ---- Reserved (unused) Holding Registers (4X) 1 – 2 I Analog Output 3 – 16 ---- Reserved (unused) 17 – 20 F Analog Output 21 – 48 ---- Reserved (unused) I : Integer, -1500 – +11500 (-15 – +115%) F : Floating Note: DO NOT access addresses other than mentioned above. Such access may cause problems such as inadequate operation. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |