R8-PC4A/Q 데이터시트(PDF) 3 Page - M-System Co.,Ltd.

부품명 R8-PC4A/Q
상세설명  Remote I/O R8 Series PULSE OUTPUT MODULE
PDF  5 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  MSYSTEM [M-System Co.,Ltd.]
홈페이지  https://www.m-system.co.jp/
Logo MSYSTEM - M-System Co.,Ltd.

R8-PC4A/Q 데이터시트(HTML) 3 Page - M-System Co.,Ltd.

  R8-PC4A/Q Datasheet HTML 1Page - M-System Co.,Ltd. R8-PC4A/Q Datasheet HTML 2Page - M-System Co.,Ltd. R8-PC4A/Q Datasheet HTML 3Page - M-System Co.,Ltd. R8-PC4A/Q Datasheet HTML 4Page - M-System Co.,Ltd. R8-PC4A/Q Datasheet HTML 5Page - M-System Co.,Ltd.  
Zoom Inzoom in Zoom Outzoom out
 3 / 5 page
background image
MODEL: R8-PC4A
R8-PC4A SPECIFICATIONS
ES-9795 Rev.4 Page 3/5
http://www.m-system.co.jp/
EXTERNAL VIEW
RUN
Module Address Setting
Rotary SW
Function Setting
DIP SW
Terminator DIP SW
1
0
9
1
0
9
SW1
x10
1 2 3 4 5 6 7 8
x1
SW2
SW4
SW3
Term
On
On
Status Indicator LED
Output Status Indicator LED
Internal Bus Connector
Output Connectors
FRONT VIEW
SIDE VIEW
CARD ADD.
PO1
PO2
PO3
PO4
1
0
9
1
0
9
OPERATING MODE SETTING
(*) Factory setting
■ Module Address
The left switch determines the tenth place digit, while the
right one does the ones place digit of the module address.
Address is selected between 0 to 30.
(Factory setting: 0)
Module Address Setting (x1)
Module Address Setting (x10)
1
0
9
1
0
9
■ Counter Reset (SW4-1)
1) Turn the power off.
2) Turn ON the Counter Reset SW (SW4-1).
3) Return the module to the base and turn the power supply ON.
The status indicator LED turns ON in amber.
4) Wait at least 5 seconds. Turn the power supply OFF.
5) Turn OFF the Counter Reset SW (SW4-1).
6) Return the module to the base and turn the power supply ON.
Note: Counter Reset SW must be turned OFF after this procedure
because the module does not start counting with ON state.
■ ON/OFF Pulse Width: (SW4-2, 3, 4, 5, 6, 7)
Setting for all outputs.
Setting for each output can be done with a PC.
ON
OFF
PULSE WIDTH
TIME *1
2
3
4
5
6
7
OFF
OFF
OFF
OFF
OFF
OFF
5 msec.(*)
ON
OFF
OFF
ON
OFF
OFF
10 msec.
OFF
ON
OFF
OFF
ON
OFF
15 msec.
ON
ON
OFF
ON
ON
OFF
100 msec.
OFF
OFF
ON
OFF
OFF
ON
500 msec.
ON
OFF
ON
ON
OFF
ON
1 sec.
OFF
ON
ON
OFF
ON
ON
1.5 sec.
ON
ON
ON
ON
ON
ON
2 sec.
*1. Minimum ensured time duration. For example, with 5 msec.
setting, the minimum pulse width is 5 msec. (Max. value =
Setting time + 2 msec.)
■ Configuration Mode
CONFIGURATION MODE
SW4
8
DIP switch setting (*)
OFF
PC Configurator and communication
ON
TERMINATOR SW
SW3
Without (*)
OFF
With
ON
■ Terminator DIP SW



Html Pages

1 2 3 4 5


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com