| 전자부품 데이터시트 검색엔진 |
|
PD69208M 데이터시트(PDF) 17 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PD69208M 데이터시트(HTML) 17 Page - Microchip Technology |
|
17 / 35 page ![]() During this period, inrush current is limited to ILIM for a duration of TLIM (as specified in the table Port Real-Time Protection), which allows PD load to charge and allows a steady state of power condition. 4.6 Over-Load Detection and Port Shut-Down After power-up, the PSE manager automatically initializes its internal protection mechanisms. These mechanisms are used to monitor and disconnect power from the PD when extreme conditions occur. These conditions include over- current or short ports terminals scenarios. 4.7 Disconnect Detection The managers support the DC disconnect function as per IEEE 802.3 standards. This mechanism continuously monitors load current and disconnects power according to IUDL, TMPDO, and TMPS parameters as specified in Port Real-Time Protection. 4.8 IC Thermal Monitoring The managers contains a thermal sensor that is sampled by the controller so that the manager die temperature is monitored at all times. To protect the PSE manager from damage, the system ports are disconnected before damage can occur. A temperature alarm threshold can be set by the controller to send interrupt indication by the xINT_OUT pin before ports are disconnected. The temperature can be read and monitored by the host as well if required. 4.9 Over-Temperature Protection In addition to the die thermal sensor, there are thermal sensors on each MOSFET that continuously monitors each port main MOSFETs junction temperature, and shuts down the port load power when the temperature exceeds the threshold. 4.10 VMAIN Out-of-Range Protection The system automatically disconnects ports power when VMAIN exceeds the pre-configured over-voltage and under- voltage thresholds. 4.11 2-Pair and 4-Pair Ports Operation modes include the following: • PoE Type 1/2 class 0–4 (up to 30 W) • PoE Type 3 class 0–4 2-Pair and class 5–6 4-Pair (up to 60 W) • PoE Type 4 class 7/8 4-Pair (75 W/90 W) • POH Mode: 4-Pair (up to 95 W) Note: For more information about 4-Pair operation modes and power, see Microchip AN3361. 4.12 Port Power Limit Port power limit (PPL) is used to configure port power limit. When a port exceeds the power limit, it gets disconnected automatically. PD69208T4/PD69204T4/PD69208M Application Information © 2020 Microchip Technology Inc. Datasheet DS00003428C-page 17 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |