| 전자부품 데이터시트 검색엔진 |
|
USB5926 데이터시트(PDF) 36 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
USB5926 데이터시트(HTML) 36 Page - Microchip Technology |
|
36 / 66 page ![]() USB5926 DS00002234E-page 36 2016-2021 Microchip Technology Inc. 8.6.1 PORT CONNECTION IN GANGED MODE Ganged Mode is enabled via SMBus or OTP configuration. GANG_PWR becomes the port control (PRTCTL) pin for all downstream ports when the hub is configured for ganged port power control mode. All port power controllers should be controlled from this pin when the hub is configured for ganged port power mode. While in this mode of operation, an over-current event on any single downstream port will cause all downstream ports to be flagged for over-current. 8.6.2 PORT CONNECTION IN INDIVIDUAL MODE 8.6.2.1 Port Power Control using USB Power Switch Individual mode is the default mode of operation. When operating in individual mode, the device will have one port power control and over-current sense pin for each downstream port. When disabling port power, the driver will actively drive a '0'. To avoid unnecessary power dissipation, the pull-up resistor will be disabled at that time. When port power is enabled, it will disable the output driver and enable the pull-up resistor, making it an open drain output. If there is an over-current situation, the USB Power Switch will assert the open drain OCS signal. The Schmidt trigger input will rec- ognize that as a low. The open drain output does not interfere. The over-current sense filter handles the transient con- ditions such as low voltage while the device is powering up. When the port is enabled, the PRT_CTLx pin input is constantly sampled. Overcurrent events can be detected in one of two ways: • Single, continuous low pulse (consecutive low samples over tocs_single), as shown in Figure 8-8. • Two short low pulses within a rolling window (two groupings of 1 or more low samples over tocs_double), as shown in Figure 8-9. FIGURE 8-7: PORT POWER CONTROL WITH USB POWER SWITCH FIGURE 8-8: SINGLE LOW PULSE OVERCURRENT DETECTION USB Power Switch 50k PRTPWR EN OCS OCS Pull‐Up Enable 5V USB Device FILTER PRT_CTLx PRT_CTLx IS VIL tocs_single |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |