  IL235Z Datasheet HTML 1Page - Integral Corp. IL235Z Datasheet HTML 2Page - Integral Corp. IL235Z Datasheet HTML 3Page - Integral Corp. IL235Z Datasheet HTML 4Page - Integral Corp. IL235Z Datasheet HTML 5Page - Integral Corp. IL235Z Datasheet HTML 6Page - Integral Corp. IL235Z Datasheet HTML 7Page - Integral Corp. IL235Z Datasheet HTML 8Page - Integral Corp. IL235Z Datasheet HTML 9Page - Integral Corp. Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 10 page
background image
IL235Z
Korzhenevskogo 12, Minsk, 220064, Republic of
Belarus
Fax:
+375 (17) 278 28 22,
Phone: +375 (17) 278 07 11, 277 24 70, 277 24 61,
277 69 16
E-mail: belms@belms.belpak.minsk.by
URL: www.bms.by
Heat conduction , (%)
Heat conduction, (%)
Time, (min)
Time, (min)
Figure 11 – Time dependence of heat conduction in
still air
Figure 12 – Time dependence of heat
conduction in agitated oil
Direct voltage, (V)
Direct current, (mА)
Figure 13 – Dependence of direct voltage on direct current
Information for application.
There is a simple technique of the device calibration for improving precision of temperature
measurement (see typical application circuits).
Calibration of the device occurs in one spot as the IC output voltage is proportional to absolute
temperature with sensor voltage extrapolation to 0 V at 0оК (-273,15оС). The errors in dependence
of output voltage on temperature are determined only by characteristic incline. Therefore bias
calibration at one temperature corrects errors in the whole temperature range. Output voltage of
calibrated or non calibrated circuit may be derived from the following equation:
VOT = VOTO
To
T
;
where Т – unknown temperature;
ТО – reference temperature (in
оК).
Nominally IC output calibrated to the value 10 mV/ оК.
To ensure measurement precision they apply some rules. Degradation of the precision when



Html Pages

1 2 3 4 5 6 7 8 9 10


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com