2 / 3 page ![]() 2 www.protekdevices.com 05057.R4 12/03 587B062LP thru 587B302LP DEVICE CHARACTERISTICS ARRESTER DEFINITIONS Clamping Voltage: The clamping voltage of an arrester is the voltage that appears across its terminals during conduction of a transient current. Standard Wave Form: The waveform of a surge current or voltage is designated by a combination of two numbers. The first number is for the time of the wave front expressed in microseconds from zero to the peak of the wave. The second number is for the time of the wavetail also expressed in microseconds from zero to the instant that the wavetail reaches one half of the crest or peak value, i.e., 8/20 µs waveform. Transient Current: The transient current of an arrestor is the peak surge current which flows through the arrester when voltage clamping occurs. OPERATION For maximum effectiveness, the protector should be installed directly after the AC line on/off switch and fuse. This will protect the electronics from the AC line switch arcing and the severe transients caused by a fuse clearing. Some heat is produced when operating at full current load, and heat sinking may be required to maintain case temperature below 85°C. The case temperature is measured at the center of the mounting surface. The unit should not be mounted to a low combusting temperature material such as wood. High energy transients will cause a large circulating current in the AC input line (2,500A is possible). To prevent electromagnetic coupling, the AC line on the input side of the protector must be dressed away from other wiring, magnetic shielding may be required. In addition, the electrical service must be connected to a low impedance earth ground. MAXIMUM RATINGS SPECIFICATIONS @ 25°C RESPONSE TO TRANSIENT VOLTAGES CLAMPING TEST CONDITION DIFFERENTIAL (Line-to-Neutral) COMMON (Neutral-to-Ground) (Line-to-Ground) Operating Line Voltage: Maximum Line Current: Transient Voltage: Transient Current: Current Leakage: Line-to-Neutral: Neutral-to-Ground: Line-to-Ground: Storage & Operating Temperature: (Measured at center of mounting surface) 240 VAC + 10% 587B062LP: 6A 587B102LP: 10A 587B162LP: 16A 587B302LP: 30A 6000V peak 3000A peak @ 240 VAC 1.0mA 1.0mA 1.0mA -40°C to 85°C PROTECTION MODE MAXIMUM CLAMPING VOLTAGE OPEN CIRCUIT VOLTAGE @ 1.2/50 µs SHORT CIRCUIT CURRENT @ 8/20 µs 800V 1000V 1000V 6000V 6000V 6000V 3000A 3000A 3000A |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |