| 전자부품 데이터시트 검색엔진 |
|
TLV841 데이터시트(PDF) 16 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TLV841 데이터시트(HTML) 16 Page - Texas Instruments |
|
16 / 34 page ![]() 8.3.3 User-Programmable Reset Time Delay for TLV841C only The reset time delay can be set to a typical value of 40 µs by leaving the CT pin floating, or a maximum value of approximately 6.2 seconds by connecting 10 µF delay capacitor. The reset time delay (tD) can be programmed by connecting a capacitor no larger than 10 µF between the CT pin and GND. The relationship between external capacitor (CCT_EXT (typ)) in µF at CT pin and the time delay (tD (typ)) in seconds is given by Equation 3. tD (typ) = -ln (0.29) x RCT (typ) x CCT_EXT (typ) + tD (no cap, typ) (3) Equation 3 is simplified to Equation 4 by plugging RCT (typ) and tD (no cap, typ) given in Section 7.5 and Section 7.6: tD (typ) = 618937 x CCT_EXT (typ) + 40 µs (4) Equation 5 solves for external capacitor value CCT_EXT in units of µF where tD (typ) is in units of seconds CCT_EXT = (tD (typ) - 40 µs) ÷ 618937 (5) The reset delay varies according to three variables: the external capacitor CCT_EXT, CT pin internal resistance RCT provided in Section 7.5, and a constant. The maximum variance due to the constant is show in Equation 6: tD (max) = -ln (0.25) x RCT (max) x CCT_EXT (max) + tD (no cap, max) (6) The recommended maximum delay capacitor for the TLV841C is limited to 10 μF as this ensures enough time for the capacitor to fully discharge when a voltage fault occurs. Also, having a too large of a capacitor value can cause very slow charge up (rise times) and system noise can cause the the internal circuit to trip earlier or later near the threshold. This leads to variation in time delay where it can make the delay accuracy worse in the presence of system noise. When a voltage fault occurs, the previously charged up capacitor discharges and if the monitored voltage returns from the fault condition before the delay capacitor discharges completely, the delay will be shorter than expected. The capacitor will begin charging from a voltage above zero and resulting in shorter than expected time delay. A larger delay capacitor can be used so long as the capacitor has enough time to fully discharge during the duration of the voltage fault. The amount of time required to discharge the delay capacitor relative to the reset delay rises as VDD fault undervoltage increases as shown in Figure 8-5. From the graph below, to ensure the CCT_EXT capacitor is fully discharged, the time period or duration of the voltage fault needs to be greater than 10% of the programmed reset time delay. VDD Fault Underoltage (V) 0.6 0.8 1 1.2 1.4 1.6 1.8 2 5 10 15 20 25 30 35 40 45 50 55 CTR_ 25°C Figure 8-5. CCT_EXT Discharge Time During Fault Condition (CCT_EXT = 1 µF) TLV841 SLVSFO5C – APRIL 2020 – REVISED JULY 2021 www.ti.com 16 Submit Document Feedback Copyright © 2021 Texas Instruments Incorporated Product Folder Links: TLV841 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |