전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

LTC4012 데이터시트(PDF) 4 Page - Analog Devices

부품명 LTC4012
상세설명  Ultra-Low Power Battery Gas Gauge
PDF  18 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  AD [Analog Devices]
홈페이지  http://www.analog.com
Logo AD - Analog Devices

LTC4012 데이터시트(HTML) 4 Page - Analog Devices

  LTC4012 Datasheet HTML 1Page - Analog Devices LTC4012 Datasheet HTML 2Page - Analog Devices LTC4012 Datasheet HTML 3Page - Analog Devices LTC4012 Datasheet HTML 4Page - Analog Devices LTC4012 Datasheet HTML 5Page - Analog Devices LTC4012 Datasheet HTML 6Page - Analog Devices LTC4012 Datasheet HTML 7Page - Analog Devices LTC4012 Datasheet HTML 8Page - Analog Devices LTC4012 Datasheet HTML 9Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 18 page
background image
LTC2959
4
Rev. 0
For more information www.analog.com
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: All currents into pins are positive, all voltages are referenced to
GND unless otherwise specified.
Note 3: Average current flowing into the VDD pin. The coulomb counter
supply current is a function of the voltage between its inputs. The ADC
supply current depends on the channel that is being measured. During
ADC conversions that measure the voltage on VSENSEN (ADC voltage mode
and register B[2] to ‘1’), current flows into SENSEN. Typically, during such
conversions, ISENSEN = VSENSEN/400kΩ.
Note 4: The coulomb counter measures static signals as well as dynamic
inputs (current pulses). It may take several short pulses to increment/
decrement the ACR.
Note 5: The equivalent charge of an LSB in the accumulated charge
register depends on the value of RSENSE: QLSB = 533nAh • (50mΩ/RSENSE).
Note 7: CB = Capacitance of one bus line in pF (10pF ≤ CB ≤ 400pF).
Note 8: Guaranteed by design, not subject to test.
ELECTRICAL CHARACTERISTICS
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
I2C Timing Characteristics
fSCL(MAX)
Maximum SCL Clock Frequency
l
400
900
kHz
tBUF(MIN)
Bus Free Time Between STOP/START
l
1.3
µs
tSU,STA(MIN) Minimum Repeated START Set-Up
Time
l
600
ns
tHD,STA(MIN) Minimum Hold Time (Repeated)
START Condition
l
600
ns
tSU,STO(MIN) Minimum Set-Up Time for STOP
Condition
600
ns
ttSU,DAT(MIN) Minimum Data Set-Up Time Input
l
100
ns
tHD,DATI(MIN) Minimum Data Hold Time Input
l
50
ns
tHD,DATO
Data Hold Time Output
l
0.3
0.9
µs
tOF
Data Output Fall Time
(Notes 7,8)
l
20 + 0.1 • CB
300
ns
Timeout
Max Time between Last SCL Clock
Edge and SDA Release
51.2
ms
The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C (Note 2).



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com