9 / 12 page ![]() 9 D7S Vibration Sensor Safety Precautions This Sensor is a precision device. Do not drop it or subject it to excessive shock or force. Doing so could break it or change its characteristics. Do not use the Sensor if it has been dropped. Operating Environment • Do not use the Sensor in locations with volatile, flammable, or corrosive gas (organic solvent vapor, sulfite gas, chlorine, sul- fide gas, ammonia gas, etc.) or other toxic gases. They may cause the Sensor to break down. • Do not use the Sensor in locations subject to fresh water, salt water, water drops, or splattering oil. • Do not use the Sensor in an environment where condensation or icing may occur. Moisture freezing on the Sensor may cause output to fluctuate or may cause the Sensor to break down. • Do not use the Sensor in locations subject to direct sunlight. Doing so may cause the Sensor to break down. • Do not use the Sensor in locations subject to direct radiant heat from heating equipment. Doing so may cause the Sensor to break down. • Do not use the Sensor in locations with severe temperature changes. Doing so may cause the Sensor to break down. • Do not use the Sensor in environments with excess mechani- cal stress. Doing so may cause the Sensor to malfunction or break down. • Do not use the Sensor in locations with large vibration or shock. These may cause the Sensor to break down. • Do not use the Sensor in locations with strong electrical or magnetic fields. These may cause the Sensor to break down. Countermeasures against Noise • The Sensor does not contain any protective circuits. Never allow the electrical load to exceed the absolute maximum rat- ings. Such loads may damage the circuits. If required, install protective circuits so that absolute maximum ratings are not exceeded. • Allow as much space as possible between the Sensor and devices that generate surges or high frequencies (such as high-frequency welders and high-frequency sewing machines). Attach a surge protector or noise filter on nearby noise-generating devices (in particular, motors, transformers, solenoids, magnetic coils, or other devices that have an induc- tance component). • Wire the Sensor away from high-voltage and large-current power lines in order to prevent inductance noise. It is also helpful to separate conduits and ducts and to use shielded cables. • When using a switching regulator, power supply switching noise may cause malfunctions, so check this before use. Handling • Static electricity can destroy the Sensor. Take countermea- sures including grounded work benches, floors, and other charged objects and workers. • Do not handle the Sensor in locations with excessive vapor, dust, dirt, etc. • Do not hold the Sensor with pliers, tweezers, or similar tools, and do not subject components to damage or excessive shock due to inadequate adjustment of the mounter. • When placing components near the edge of the PCB or near a connector, make sure that stress is not applied to the Sensor when the device is assembled or when the connector is con- nected or disconnected. • Do not apply any external force to components after soldering until everything has cooled off and do not allow mechanical stress due to PCB warping or other factors. • Under some usage conditions, ultrasound may cause the Sen- sor to resonate and be destroyed. OMRON cannot specify the detailed conditions under which the Sensor will be used, so we assume no responsibility if the Sensor is used in environments where ultrasound is used. If the Sensor must be used in an environment with ultrasound, check its performance in the actual environment beforehand. • Stress due to plastic hardening may change Sensor character- istics. Do not mold seal the Sensor after mounting. • When applying a moisture preventing coating or other coating after mounting the Sensor, select a coating with minimal stress and check operation carefully. • Do not attempt to disassemble or modify the Sensor. • Do not use the Sensor in safety devices or for applications in which Sensor operation would directly affect human life. • Carefully read the precaution in the Instruction Manual before using the Sensor. • In addition, if you use the Sensor under conditions other than those in these specifications, check Sensor operation under those conditions beforehand. Shipping and Storage • Do not store the Sensor in locations with harmful corrosive gas (organic solvent vapor, sulfite gas, sulfide gas, etc.) • The Sensor is not drip proof, so do not store it anywhere that water might get on it. • Store the Sensor within appropriate temperature and humidity ranges. * Before storing the Sensor in an environment other than the environment recommended by OMRON, evaluate the results in the actual storage environment and judge whether or not storage there is appropriate. • Do not store the Sensor in locations with excessive vapor, dust, dirt, etc. Caution Precautions for Correct Use |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |