전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

MB30-CS 데이터시트(PDF) 2 Page - Mitsubishi Electric Semiconductor

부품명 MB30-CS
상세설명  TECHNICAL NOTES
PDF  105 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  MITSUBISHI [Mitsubishi Electric Semiconductor]
홈페이지  http://www.mitsubishichips.com
Logo MITSUBISHI - Mitsubishi Electric Semiconductor

MB30-CS 데이터시트(HTML) 2 Page - Mitsubishi Electric Semiconductor

  MB30-CS Datasheet HTML 1Page - Mitsubishi Electric Semiconductor MB30-CS Datasheet HTML 2Page - Mitsubishi Electric Semiconductor MB30-CS Datasheet HTML 3Page - Mitsubishi Electric Semiconductor MB30-CS Datasheet HTML 4Page - Mitsubishi Electric Semiconductor MB30-CS Datasheet HTML 5Page - Mitsubishi Electric Semiconductor MB30-CS Datasheet HTML 6Page - Mitsubishi Electric Semiconductor MB30-CS Datasheet HTML 7Page - Mitsubishi Electric Semiconductor MB30-CS Datasheet HTML 8Page - Mitsubishi Electric Semiconductor MB30-CS Datasheet HTML 9Page - Mitsubishi Electric Semiconductor Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 105 page
background image
1
1. INTRODUCTION ............................................... 2
2. FEATURES ....................................................... 3
2.1 Arc-Extinguishing Device – ISTAC .................. 3
2.2 Digital ETR ......................................................... 4
3. CONSTRUCTION AND OPERATION ............... 6
4. CHARACTERISTICS AND
PERFORMANCE ............................................. 11
4.1 Overcurrent-Trip Characteristics ................... 11
4.2 Short-Circuit Trip Characteristics .................. 11
4.3 Effects of Mounting Attitudes ........................ 12
4.4 DC Tripping Characteristics of AC-Rated
MCCBs .............................................................. 12
4.5 Frequency Characteristics ............................. 12
4.6 Switching Characteristics ............................... 13
4.7 Dielectric Strength ........................................... 13
5. CIRCUIT BREAKERS SELECTION ............... 14
5.1 Circuit Breakers Selection Table ................... 14
6. PROTECTIVE CO-ORDINATION ................... 39
6.1 General ............................................................. 39
6.2 Interrupting Capacity Consideration ............. 40
6.3 Selective-Interruption ...................................... 41
6.4 Cascade Back-up Protection .......................... 68
6.5 I2t Let-Through Characteristics and Current
Limiting Characteristics .................................. 70
6.6 Protective Coordination with Wiring ............. 71
6.7 Protective Coordination with
Motor Starters .................................................. 74
6.8 Coordination with Devices on the
High-Voltage Circuit ........................................ 76
7. SELECTION .................................................... 79
7.1 For Motor Branch Circuits .............................. 79
7.2 For Lighting and Heating Branch Circuits .... 79
7.3 For Main Circuit ............................................... 80
7.4 For Welding Circuits ....................................... 80
7.5 For Transformer-Primary Use ........................ 82
7.6 For Capacitor Circuits ..................................... 83
7.7 For Thyristor Circuits ...................................... 84
7.8 MDU Breaker .................................................... 90
7.9 Selection of MCCBs in inverter circuit .......... 93
8. ENVIRONMENTAL CHARACTERISTICS ...... 95
8.1 Atmospheric Environment .............................. 95
8.2 Vibration-Withstand Characteristics ............. 96
8.3 Shock-Withstand Characteristics .................. 97
9. SHORT-CIRCUIT CURRENT
CALCULATIONS ............................................ 98
9.1 Purpose ............................................................ 98
9.2 Definitions ........................................................ 98
9.3 Impedances and Equivalent Circuits of
Circuit Components ........................................ 98
9.4 Classification of Short-Circuit Current ........ 101
9.5 Calculation Procedures ................................ 102
CONTENTS
We have the pleasure of providing all our customers with the technical information for Mitsubishi
moulded case circuit breakers. This indicates the fundamental data of our circuit breakers
regarding the applicable standards, constructional principles, and operational performances.
Please refer to the catalogue of our circuit breakers for details of specifications.
Also please stand in need of the handling and maintenance manual for maintaning the circuit
breakers in service continuously.
We do hope they are available for all our customers to built more efficient systems.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com