| 전자부품 데이터시트 검색엔진 |
|
MB30-CS 데이터시트(PDF) 102 Page - Mitsubishi Electric Semiconductor |
|
|
|||||||||||||||||||||||||||||
MB30-CS 데이터시트(HTML) 102 Page - Mitsubishi Electric Semiconductor |
|
102 / 105 page ![]() 101 Ias = Is · { 1 + 2e e + 2 1 + } = Is · K3 x 2 πR – x 2 πR – 3 1 2 1 that is: K3 = { 1 + 2e e + 2 1 + } x 2 πR – x 2 πR – 3 1 2 1 K3 is the asymmetrical coefficient, derived from the symmetrical value and the circuit power factor. 3. Peak Value of Asymmetrical Short-Circuit Current This value ( Ip in Fig. 9.3) depends upon the phase angle at short circuit closing and on the circuit power factor; it is maximum when θ = 0. It will reach peak value in each case, ωt = 2 π + ϕ after the short circuit occurrence. It can be computed as before, by means of the circuit power factor and the symmetrical short- circuit current. Ip = Is [1 + sin ϕ·e ] = Is · Kp 2 π x R –( + ϕ)· thus: Kp = 2 [1 + sin ϕ·e ] 2 π x R –( + ϕ)· Kp, the peak asymmetrical short-circuit current coeffi- cient, is also known as the closing-capacity coefficient, since Ip is called the closing capacity. Thus, in each case, the asymmetrical coefficients can be derived from the symmetrical values and the circuit power fac- tor. These coefficients are shown Fig. 9.4. As As 1/2 Cycle Ip Ad Fig. 9.3 Short-Circuit Current 9.4 Classification of Short-Circuit Current A DC current (Fig. 9.3) of magnitude determined by the voltage phase angle at the instant of short circuit and-the circuit power factor will be superimposed on the AC short-circuit current. This DC component will rapidly decay; however, where a high-speed circuit-interruption device such as an MCCB or fuse is employed, the DC component must be considered. Further, the mechanical stress of the electric circuit will be affected by the maximum instantaneous short-circuit current; hence, the short- circuit current is divided, as below. 1. RMS Symmetrical Short-Circuit Current ( Is) This is the value exclusive of the DC component; it is As/M2 of Fig. 9.3. 2. RMS Asymmetrical Short-Circuit Current ( Ias) This value includes the DC component. It is defined as: 2 As Ias = )2 + Ad2 ( Accordingly, when the DC component becomes maxi- mum (i.e., θ – ϕ = ± 2 π , where the voltage phase angle at short circuit is θ, and the circuit power factor is cosϕ), Ias will also become maximum 2 1 cycle after the short circuit occurs, as follows: Ias = Is · 1 + 2e = Is · K1, that is: K1 = 1 + 2e x 2 πR – x 2 πR – where K1 is the single-phase maximum asymmetrical coefficient, and Ias can be calculated from the asym- metrical value and the circuit power factor. In a 3- phase circuit, since the voltage phase angle at switch- on differs between phases, Ias will do the same. If the average of these values is taken 2 1 cycle later, to give the 3-phase average asymmetrical short-circuit cur- rent, the following relationship is obtained: 3.0 2.0 1.0 2.0 1.9 1.8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 20 10 8 7 6 5 4 3 2.5 2 1.5 1 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 K1: Single-phase maximum asymmetrical coefficient K3: 3-phase asymmetrical coefficient Kp: Closing capacity coefficient Power factor R X Kp K1 K3 Fig. 9.4 Short-Circuit Current Coefficients |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |