| 전자부품 데이터시트 검색엔진 |
|
RH 데이터시트(PDF) 4 Page - IDEC Corporation |
|
|
|||||||||||||||||||||||||||||
RH 데이터시트(HTML) 4 Page - IDEC Corporation |
|
4 / 10 page ![]() RH Relays & Sockets 876 www.IDEC.com 1705151135 Specifications Contact Material Silver cadmium oxide Contact Resistance 1 50mΩ maximum Minimum Applicable Load 24V DC, 30 mA; 5V DC, 100 mA (reference value) Operating Time 2 SPDT DPDT 20ms maximum 3PDT 4PDT 25ms maximum Release Time 2 SPDT DPDT 20ms maximum 3PDT 4PDT 25ms maximum Power Consumption (approx.) SPDT AC: 1.1VA (50Hz), 1VA (60Hz) DC: 0.8W DPDT AC: 1.4VA (50Hz), 1.2VA (60Hz) DC: 0.9W 3PDT AC: 2VA (50Hz), 1.7VA (60Hz) DC: 1.5W 4PDT AC: 2.5VA (50Hz), 2VA (60Hz) DC: 1.5W Insulation Resistance 100MΩ minimum (500V DC megger) Dielectric Strength 3 SPDT Between live and dead parts: 2,000V AC, 1 minute Between contact and coil: 2,000V AC, 1 minute Between contacts of the same pole: 1,000V AC, 1 minute DPDT 3PDT 4PDT Between live and dead parts: 2,000V AC, 1 minute Between contact and coil: 2,000V AC, 1 minute Between contacts of different poles: 2,000V AC, 1 minute Between contacts of the same pole: 1,000V AC, 1 minute Operating Frequency Electrical: 1,800 operations/hour maximum Mechanical: 18,000 operations/hour maximum Vibration Resistance Damage limits: 10 to 55Hz, amplitude 0.5 mm Operating extremes: 10 to 55Hz, amplitude 0.5 mm Shock Resistance Damage limits: 1,000m/s2 (100G) Operating extremes: 200m/s2 (20G - SPDT, DPDT) 100m/s2 (10G - 3PDT, 4PDT) Mechanical Life 50,000,000 operations minimum Electrical Life DPDT 500,000 operations minimum (120V AC, 10A) SPDT 3PDT 4PDT 200,000 operations minimum (120V AC, 10A) Operating Temperature 4 SPDT DPDT 3PDT 4PDT –25 to +70°C (no freezing) Operating Humidity 45 to 85% RH (no condensation) Weight (approx.) SPDT: 24g, DPDT: 37g, 3PDT: 50g, 4PDT: 74g Note: Above values are initial values. 1. Measured using 5V DC, 1A voltage drop method 2. Measured at the rated voltage (at 20°C), excluding contact bouncing Release time of relays with diode: 40 ms maximum 3. Relays with indicator or diode: 1000V AC, 1 minute 4. For use under different temperature conditions, refer to Continuous Load Current vs. Operating Temperature Curve. The operating temperature range of relays with indicator or diode is –25 to +40°C. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |