| 전자부품 데이터시트 검색엔진 |
|
L99MOD53XP 데이터시트(PDF) 19 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99MOD53XP 데이터시트(HTML) 19 Page - STMicroelectronics |
|
19 / 35 page ![]() DS12617 Rev 5 19/35 L99MOD53XP Application information 34 3 Application information 3.1 Dual power supply: VS and VCC The power supply voltage VS supplies the half bridges and the high-side drivers. An internal charge-pump is used to drive the high-side switches. The logic supply voltage VCC (stabilized 5 V) is used for the logic part and the SPI of the device. Due to the independent logic supply voltage the control and status information is not lost, if there are temporary spikes or glitches on the power supply voltage. In case of power-on (VCC increases from under voltage to VPOR Off = 4.2 V) the circuit is initialized by an internally generated power-on-reset (POR). If the voltage VCC decreases under the minimum threshold (VPOR ON = 3.4 V), the outputs are switched to 3-state (high impedance) and the status registers are cleared. 3.2 Standby mode The standby mode of the L99MOD53XP is activated by clearing the bit 23 of the input data register 0. All latched data are cleared and the inputs and outputs are switched to high impedance. In the standby mode the current at VS (VCC) is less than 6 µA (50 µA) for CSN = high (DO in 3-state). By switching the VCC voltage a very low quiescent current can be achieved. If bit 23 is set, the device is switched to active mode. 3.3 Inductive loads Each half bridge is built by an internally connected high-side and a low-side power DMOS transistor. Due to the built-in reverse diodes of the output transistors, inductive loads can be driven at the outputs OUT1 to OUT5 without external free-wheeling diodes. The high-side drivers OUT6 to OUT8 are intended to drive resistive loads. Hence only a limited energy (E<1mJ) can be dissipated by the internal ESD diodes in freewheeling condition. For inductive loads (L>100µH) an external free-wheeling diode connected to GND and the corresponding output is needed. 3.4 Diagnostic functions All diagnostic functions (over/open-load, power supply over-/under voltage, temperature warning and thermal shutdown) are internally filtered and the condition has to be valid for at least 32 µs (open-load: 1 ms, respectively) before the corresponding status bit in the status registers is set. The filters are used to improve the noise immunity of the device. Open-load and temperature warning functions are intended for information purpose and don't change the state of the output drivers. On the contrary, the overload condition disables the corresponding driver (over-current) and overtemperature switches off all drivers (thermal shutdown). Without setting the over-current recovery bits in the input data register, the microcontroller has to clear the over-current status bits to reactivate the corresponding drivers. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |